CIM_VideoController class

The CIM_VideoController class represents the capabilities and management of the video controller.

Important  The DMTF (Distributed Management Task Force) CIM (Common Information Model) classes are the parent classes upon which WMI classes are built. WMI currently supports only the CIM 2.x version schemas.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of its inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

class CIM_VideoController : CIM_Controller
{
  uint16   AcceleratorCapabilities[];
  uint16   Availability;
  string   CapabilityDescriptions[];
  string   Caption;
  uint32   ConfigManagerErrorCode;
  boolean  ConfigManagerUserConfig;
  string   CreationClassName;
  uint32   CurrentBitsPerPixel;
  uint32   CurrentHorizontalResolution;
  uint64   CurrentNumberOfColors;
  uint32   CurrentNumberOfColumns;
  uint32   CurrentNumberOfRows;
  uint32   CurrentRefreshRate;
  uint16   CurrentScanMode;
  uint32   CurrentVerticalResolution;
  string   Description;
  string   DeviceID;
  boolean  ErrorCleared;
  string   ErrorDescription;
  datetime InstallDate;
  uint32   LastErrorCode;
  uint32   MaxMemorySupported;
  uint32   MaxNumberControlled;
  uint32   MaxRefreshRate;
  uint32   MinRefreshRate;
  string   Name;
  uint32   NumberOfVideoPages;
  string   PNPDeviceID;
  uint16   PowerManagementCapabilities[];
  boolean  PowerManagementSupported;
  uint16   ProtocolSupported;
  string   Status;
  uint16   StatusInfo;
  string   SystemCreationClassName;
  string   SystemName;
  datetime TimeOfLastReset;
  uint16   VideoMemoryType;
  string   VideoProcessor;
};

Members

The CIM_VideoController class has these types of members:

Methods

The CIM_VideoController class has these methods.

MethodDescription
Reset

Requests a reset of the logical device. Not implemented by WMI.

SetPowerState

Defines the desired power state for a logical device and when a device should be put into that state. Not implemented by WMI.

 

Properties

The CIM_VideoController class has these properties.

AcceleratorCapabilities
Data type: uint16 array
Access type: Read-only

Graphics and 3-D capabilities of the video controller.

Unknown (0)
Other (1)
Graphics accelerator (2)
3-D accelerator (3)
Availability
Data type: uint16
Access type: Read-only

Availability and status of the device. Inherited from CIM_LogicalDevice.

ValueMeaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

Running or Full Power

4 (0x4)

Warning

5 (0x5)

In Test

6 (0x6)

Not Applicable

7 (0x7)

Power Off

8 (0x8)

Off Line

9 (0x9)

Off Duty

10 (0xA)

Degraded

11 (0xB)

Not Installed

12 (0xC)

Install Error

13 (0xD)

Power Save - Unknown

The device is known to be in a power save mode, but its exact status is unknown.

14 (0xE)

Power Save - Low Power Mode

The device is in a power save state but still functioning, and may exhibit degraded performance.

15 (0xF)

Power Save - Standby

The device is not functioning, but could be brought to full power quickly.

16 (0x10)

Power Cycle

17 (0x11)

Power Save - Warning

The device is in a warning state, though also in a power save mode.

 

CapabilityDescriptions
Data type: string array
Access type: Read-only

Free-form strings that provide detailed descriptions for the video accelerator features indicated in the AcceleratorCapabilities array.

Note   Each entry of this array is related to the entry in the AcceleratorCapabilities array that is located at the same index.
Caption
Data type: string
Access type: Read-only

Short textual description of the object. This property is inherited from CIM_ManagedSystemElement.

ConfigManagerErrorCode
Data type: uint32
Access type: Read-only

Windows Configuration Manager error code.

ValueMeaning
0 (0x0)

Device is working properly.

1 (0x1)

Device is not configured correctly.

2 (0x2)

Windows cannot load the driver for this device.

3 (0x3)

Driver for this device might be corrupted, or the system may be low on memory or other resources.

4 (0x4)

Device is not working properly. One of its drivers or the registry might be corrupted.

5 (0x5)

Driver for the device requires a resource that Windows cannot manage.

6 (0x6)

Boot configuration for the device conflicts with other devices.

7 (0x7)

Cannot filter.

8 (0x8)

Driver loader for the device is missing.

9 (0x9)

Device is not working properly. The controlling firmware is incorrectly reporting the resources for the device.

10 (0xA)

Device cannot start.

11 (0xB)

Device failed.

12 (0xC)

Device cannot find enough free resources to use.

13 (0xD)

Windows cannot verify the device's resources.

14 (0xE)

Device cannot work properly until the computer is restarted.

15 (0xF)

Device is not working properly due to a possible re-enumeration problem.

16 (0x10)

Windows cannot identify all of the resources that the device uses.

17 (0x11)

Device is requesting an unknown resource type.

18 (0x12)

Device drivers must be reinstalled.

19 (0x13)

Failure using the VxD loader.

20 (0x14)

Registry might be corrupted.

21 (0x15)

System failure. If changing the device driver is ineffective, see the hardware documentation. Windows is removing the device.

22 (0x16)

Device is disabled.

23 (0x17)

System failure. If changing the device driver is ineffective, see the hardware documentation.

24 (0x18)

Device is not present, not working properly, or does not have all of its drivers installed.

25 (0x19)

Windows is still setting up the device.

26 (0x1A)

Windows is still setting up the device.

27 (0x1B)

Device does not have valid log configuration.

28 (0x1C)

Device drivers are not installed.

29 (0x1D)

Device is disabled. The device firmware did not provide the required resources.

30 (0x1E)

Device is using an IRQ resource that another device is using.

31 (0x1F)

Device is not working properly. Windows cannot load the required device drivers.

 

ConfigManagerUserConfig
Data type: boolean
Access type: Read-only

If TRUE, the device is using a user-defined configuration. This property is inherited from CIM_LogicalDevice.

CreationClassName
Data type: string
Access type: Read-only

Name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified. This property is inherited from CIM_LogicalDevice.

CurrentBitsPerPixel
Data type: uint32
Access type: Read-only

Number of bits used to display each pixel.

CurrentHorizontalResolution
Data type: uint32
Access type: Read-only

Current number of horizontal pixels.

CurrentNumberOfColors
Data type: uint64
Access type: Read-only

Number of colors supported at the current resolution.

For more information about using uint64 values in scripts, see Scripting in WMI.

CurrentNumberOfColumns
Data type: uint32
Access type: Read-only

If in character mode, number of columns for the video controller; otherwise, enter 0.

CurrentNumberOfRows
Data type: uint32
Access type: Read-only

If in character mode, number of rows for the video controller; otherwise, enter 0.

CurrentRefreshRate
Data type: uint32
Access type: Read-only

Current refresh rate, in hertz.

CurrentScanMode
Data type: uint16
Access type: Read-only

Current scan mode.

Other (1)
Unknown (2)
Interlaced (3)
Noninterlaced (4)
CurrentVerticalResolution
Data type: uint32
Access type: Read-only

Current number of vertical pixels.

Description
Data type: string
Access type: Read-only

Textual description of the object. This property is inherited from CIM_ManagedSystemElement.

DeviceID
Data type: string
Access type: Read-only

Address or other identifying information to uniquely name the logical device. This property is inherited from CIM_LogicalDevice.

ErrorCleared
Data type: boolean
Access type: Read-only

If TRUE, the error reported in the LastErrorCode property is now cleared. This property is inherited from CIM_LogicalDevice.

ErrorDescription
Data type: string
Access type: Read-only

Free-form string that supplies information about the error recorded in the LastErrorCode property and corrective actions to perform. This property is inherited from CIM_LogicalDevice.

InstallDate
Data type: datetime
Access type: Read-only

Date and time the object was installed. This property does not need a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.

LastErrorCode
Data type: uint32
Access type: Read-only

Last error code reported by the logical device. This property is inherited from CIM_LogicalDevice.

MaxMemorySupported
Data type: uint32
Access type: Read-only

Maximum amount of memory supported, in bytes.

MaxNumberControlled
Data type: uint32
Access type: Read-only

Maximum number of directly addressable entities supported by the controller. A value of 0 should be used if the number is unknown or unlimited. This property is inherited from CIM_Controller.

MaxRefreshRate
Data type: uint32
Access type: Read-only

Maximum refresh rate of the video controller, in hertz.

MinRefreshRate
Data type: uint32
Access type: Read-only

Minimum refresh rate of the video controller, in hertz.

Name
Data type: string
Access type: Read-only

Label by which the object is known. When subclassed, this property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement.

NumberOfVideoPages
Data type: uint32
Access type: Read-only

Number of video pages supported given the current resolutions and available memory.

PNPDeviceID
Data type: string
Access type: Read-only

Windows Plug and Play device identifier of the logical device. This property is inherited from CIM_LogicalDevice.

Example: "*PNP030b"

PowerManagementCapabilities
Data type: uint16 array
Access type: Read-only

Array of the specific power-related capabilities of a logical device. This property is inherited from CIM_LogicalDevice.

ValueMeaning
0 (0x0)

Unknown

1 (0x1)

Not Supported

2 (0x2)

Disabled

3 (0x3)

Enabled

The power management features are currently enabled but the exact feature set is unknown or the information is unavailable.

4 (0x4)

Power Saving Modes Entered Automatically

The device can change its power state based on usage or other criteria.

5 (0x5)

Power State Settable

The SetPowerState method is supported. This method is found on the parent CIM_LogicalDevice class and can be implemented. For more information, see Designing Managed Object Format (MOF) Classes.

6 (0x6)

Power Cycling Supported

The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle).

7 (0x7)

Timed Power On Supported

The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle) and Time set to a specific date and time, or interval, for power-on.

 

PowerManagementSupported
Data type: boolean
Access type: Read-only

If TRUE, the device can be power managed, that is, put into a power-save state. If FALSE, the integer value 1 ("Not Supported") should be the only entry in the PowerManagementCapabilities array.

This property does not indicate whether power management features are currently enabled, or if enabled, which features are supported. For more information, see the PowerManagementCapabilities array. This property is inherited from CIM_LogicalDevice.

ProtocolSupported
Data type: uint16
Access type: Read-only

Protocol used by the controller to access 'controlled' devices. This property is inherited from CIM_Controller. Values are:

ValueMeaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

EISA

4 (0x4)

ISA

5 (0x5)

PCI

6 (0x6)

ATA/ATAPI

7 (0x7)

Flexible Diskette

8 (0x8)

1496

9 (0x9)

SCSI Parallel Interface

10 (0xA)

SCSI Fibre Channel Protocol

11 (0xB)

SCSI Serial Bus Protocol

12 (0xC)

SCSI Serial Bus Protocol-2 (1394)

13 (0xD)

SCSI Serial Storage Architecture

14 (0xE)

VESA

15 (0xF)

PCMCIA

16 (0x10)

Universal Serial Bus

17 (0x11)

Parallel Protocol

18 (0x12)

ESCON

19 (0x13)

Diagnostic

20 (0x14)

I2C

21 (0x15)

Power

22 (0x16)

HIPPI

23 (0x17)

MultiBus

24 (0x18)

VME

25 (0x19)

IPI

26 (0x1A)

IEEE-488

27 (0x1B)

RS232

28 (0x1C)

IEEE 802.3 10BASE5

29 (0x1D)

IEEE 802.3 10BASE2

30 (0x1E)

IEEE 802.3 1BASE5

31 (0x1F)

IEEE 802.3 10BROAD36

32 (0x20)

IEEE 802.3 100BASEVG

33 (0x21)

IEEE 802.5 Token-Ring

34 (0x22)

ANSI X3T9.5 FDDI

35 (0x23)

MCA

36 (0x24)

ESDI

37 (0x25)

IDE

38 (0x26)

CMD

39 (0x27)

ST506

40 (0x28)

DSSI

41 (0x29)

QIC2

42 (0x2A)

Enhanced ATA/IDE

43 (0x2B)

AGP

44 (0x2C)

TWIRP (two-way infrared)

45 (0x2D)

FIR (fast infrared)

46 (0x2E)

SIR (serial infrared)

47 (0x2F)

IrBus

 

Status
Data type: string
Access type: Read-only

Current status of the object. This property is inherited from CIM_ManagedSystemElement.

Values include the following:

"OK"

"Error"

"Degraded"

"Unknown"

"Pred Fail"

"Starting"

"Stopping"

"Service"

"Stressed"

"NonRecover"

"No Contact"

"Lost Comm"

StatusInfo
Data type: uint16
Access type: Read-only

State of the logical device. If this property does not apply to the logical device, the value 5 (Not Applicable) should be used. This property is inherited from CIM_LogicalDevice.

ValueMeaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

Enabled

4 (0x4)

Disabled

5 (0x5)

Not Applicable

 

SystemCreationClassName
Data type: string
Access type: Read-only

Scoping system's creation class name. This property is inherited from CIM_LogicalDevice.

SystemName
Data type: string
Access type: Read-only

Scoping system's name. This property is inherited from CIM_LogicalDevice.

TimeOfLastReset
Data type: datetime
Access type: Read-only

Date and time the controller was last reset, meaning the controller was powered down or reinitialized. This property is inherited from CIM_Controller.

VideoMemoryType
Data type: uint16
Access type: Read-only

Type of video memory.

Other (1)
Unknown (2)
VRAM (3)
DRAM (4)
SRAM (5)
WRAM (6)
EDO RAM (7)
Burst Synchronous DRAM (8)
Pipelined Burst SRAM (9)
CDRAM (10)
3DRAM (11)
SDRAM (12)
SGRAM (13)
VideoProcessor
Data type: string
Access type: Read-only

Free-form string that describes the video processor or controller.

Remarks

The CIM_VideoController class is derived from CIM_Controller.

WMI does not implement this class. For WMI classes derived from CIM_VideoController, see Win32 Classes.

This documentation is derived from the CIM class descriptions published by the DMTF. Microsoft may have made changes to correct minor errors, conform to Microsoft SDK documentation standards, or provide more information.

Requirements

Minimum supported client

Windows Vista

Minimum supported server

Windows Server 2003

Namespace

Root\CIMV2

MOF

CIMWin32.mof

DLL

CIMWin32.dll

 

 

显示:
© 2015 Microsoft