WIA_IPS_OVER_SCAN

The WIA_IPS_OVER_SCAN property is used to enable and configure over scanning (scanning beyond physical document boundaries). The WIA minidriver creates and maintains this property.

Property Type: VT_I4

Valid Values: WIA_PROP_LIST

Access Rights: Read/Write

Remarks

The following table describes the valid values for the WIA_IPS_OVER_SCAN property.

ValueDefinition

WIA_OVER_SCAN_DISABLED

Over scanning is disabled. This is the required default value if the property is supported.

WIA_ OVER_SCAN_TOP_BOTTOM

Over scan at the top and bottom sides of the document.

WIA_ OVER_SCAN_LEFT_RIGHT

Over scan at the left and right sides of the document.

WIA_ OVER_SCAN_ ALL

Over scan at all sides of the document.

 

This property is valid for all programmable image data source items, including Flatbed (WIA_CATEGORY_FLATBED) and Feeder (WIA_CATEGORY_FEEDER) and is optional. When the property is supported, WIA_OVER_SCAN_DISABLED is the required default value.