VDS_INTERCONNECT_FLAG enumeration

[Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage Management API.]

Defines the set of interconnect types that subsystems can support.

Syntax


typedef enum  { 
  VDS_ITF_PCI_RAID       = 0x1,
  VDS_ITF_FIBRE_CHANNEL  = 0x2,
  VDS_ITF_ISCSI          = 0x4,
  VDS_ITF_SAS            = 0x8
} VDS_INTERCONNECT_FLAG;

Constants

VDS_ITF_PCI_RAID

The subsystem supports a PCI RAID interconnect.

VDS_ITF_FIBRE_CHANNEL

The subsystem supports a Fibre Channel interconnect.

VDS_ITF_ISCSI

The subsystem supports an iSCSI interconnect.

VDS_ITF_SAS

The subsystem supports a serial attached iSCSI (SAS) interconnect.

Remarks

Note  Additional constants might be added to the VDS_INTERCONNECT_FLAG enumeration in future Windows versions. For this reason, your application must be designed to gracefully handle an unrecognized VDS_INTERCONNECT_FLAG enumeration constant.
 

Requirements

Minimum supported client

Windows 7 [desktop apps only]

Minimum supported server

Windows Server 2008 R2 [desktop apps only]

Header

Vds.h;
VdsHwPrv.h (for hardware providers)

See also

IVdsSubSystemInterconnect::GetSupportedInterconnects
VDS Enumerations
VDS_HWPROVIDER_TYPE

 

 