IConnector::ConnectTo method

The ConnectTo method connects this connector to a connector in another device-topology object.

Syntax


HRESULT ConnectTo(
  [in] IConnector *pConnectTo
);

Parameters

pConnectTo [in]

The other connector. This parameter points to the IConnector interface of the connector object that represents the connector in the other device topology. The caller is responsible for releasing its counted reference to the IConnector interface when it is no longer needed. The ConnectTo method obtains its own reference to this interface.

Return value

If the method succeeds, it returns S_OK. If it fails, possible return codes include, but are not limited to, the values shown in the following table.

Return codeDescription
E_POINTER

Pointer pConnectTo is NULL.

E_INVALIDARG

The current connector and remote connector pointed to by pConnectTo, have the same direction of data flow. A connector with data-flow direction "In" must be connected to another connector with data-flow direction "Out" to create a valid connection in the topology. To determine the data flow of a connector, call IConnector::GetDataFlow.

E_NOINTERFACE

The object pointed to by pConnectTo is not a valid connector object.

HRESULT_FROM_WIN32(ERROR_DEVICE_ALREADY_ATTACHED)

One of the two connectors is already attached to another connector. For information about this macro, see the Windows SDK documentation.

 

Requirements

Minimum supported client

Windows Vista [desktop apps only]

Minimum supported server

Windows Server 2008 [desktop apps only]

Header

Devicetopology.h