CIM_RedundancyGroup class

The CIM_RedundancyGroup class represents a collection of managed system elements, which indicates that the aggregated components, together, provide redundancy. All elements aggregated in a redundancy group should be instantiations of the same object class.

Important  The DMTF (Distributed Management Task Force) CIM (Common Information Model) classes are the parent classes upon which WMI classes are built. WMI currently supports only the CIM 2.x version schemas.
 

The following syntax is simplified from Managed Object Format (MOF) code and includes all of its inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

[Abstract, UUID("{4C3A040A-E3D1-11d2-8601-0000F8102E5F}"), AMENDMENT]
class CIM_RedundancyGroup : CIM_LogicalElement
{
  string   Caption;
  string   Description;
  datetime InstallDate;
  string   Name;
  string   Status;
  string   CreationClassName;
  uint16   RedundancyStatus;
};

Members

The CIM_RedundancyGroup class has these types of members:

Properties

The CIM_RedundancyGroup class has these properties.

Caption
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64), DisplayName ("Caption")

A short textual description of the object.

This property is inherited from CIM_ManagedSystemElement.

CreationClassName
Data type: string
Access type: Read-only
Qualifiers: Key, MaxLen (256)

Name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified.

Description
Data type: string
Access type: Read-only
Qualifiers: DisplayName ("Description")

A textual description of the object.

This property is inherited from CIM_ManagedSystemElement.

InstallDate
Data type: datetime
Access type: Read-only
Qualifiers: MappingStrings ("MIF.DMTF|ComponentID|001.5"), DisplayName ("Install Date")

Indicates when the object was installed. Lack of a value does not indicate that the object is not installed.

This property is inherited from CIM_ManagedSystemElement.

Name
Data type: string
Access type: Read-only
Qualifiers: DisplayName ("Name")

Label by which the object is known. When subclassed, this property can be overridden to be a key property.

This property is inherited from CIM_ManagedSystemElement.

RedundancyStatus
Data type: uint16
Access type: Read-only

Information about the state of the redundancy group.

Unknown (0)

Unknown.

Other (1)

Other.

Fully Redundant (2)

All of the configured redundancy is available.

Degraded Redundancy (3)

Reduced amount of redundancy is available due to some failures.

Redundancy Lost (4)

Redundancy is unavailable due to a sufficient number of failures. The next failure will cause overall failure.

Status
Data type: string
Access type: Read-only
Qualifiers: MaxLen (10), DisplayName ("Status")

String that indicates the current status of the object. Operational and non-operational status can be defined. Operational status can include "OK", "Degraded", and "Pred Fail". "Pred Fail" indicates that an element is functioning properly, but is predicting a failure (for example, a SMART-enabled hard disk drive).

Non-operational status can include "Error", "Starting", "Stopping", and "Service". "Service" can apply during disk mirror-resilvering, reloading a user permissions list, or other administrative work. Not all such work is online, but the managed element is neither "OK" nor in one of the other states.

This property is inherited from CIM_ManagedSystemElement.

Values include the following:

OK ("OK")

Error ("Error")

Degraded ("Degraded")

Unknown ("Unknown")

Pred Fail ("Pred Fail")

Starting ("Starting")

Stopping ("Stopping")

Service ("Service")

Stressed ("Stressed")

NonRecover ("NonRecover")

No Contact ("No Contact")

Lost Comm ("Lost Comm")

Remarks

The CIM_RedundancyGroup class is derived from CIM_LogicalElement.

WMI does not implement this class.

This documentation is derived from the CIM class descriptions published by the DMTF. Microsoft may have made changes to correct minor errors, conform to Microsoft SDK documentation standards, or provide more information.

Requirements

Minimum supported client

Windows Vista

Minimum supported server

Windows Server 2008

Namespace

Root\CIMV2

MOF

CIMWin32.mof

DLL

CIMWin32.dll

See also

CIM_LogicalElement

 

 

Show: