SMS_G_System_SoftwareUsageData Server WMI Class
Updated: November 1, 2013
Applies To: System Center 2012 Configuration Manager, System Center 2012 Configuration Manager SP1, System Center 2012 R2 Configuration Manager
The SMS_G_System_SoftwareUsageData Windows Management Instrumentation (WMI) class is an SMS Provider server class, in System Center 2012 R2 Configuration Manager, that provides a view of raw metering data that combines file and user information with the raw data.
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.
Class SMS_G_System_SoftwareUsageData : SMS_G_System
{
String CompanyName;
Boolean EndNotCaptured;
DateTime EndTimeGMT;
DateTime EndTimeLocal;
String FileDescription;
SInt64 FileID;
String FileName;
UInt32 FileSize;
String FileVersion;
Boolean InTSSession;
String MeterDataID;
UInt32 ProductLanguage;
String ProductName;
String ProductVersion;
UInt32 ResourceID;
Boolean StartNotCaptured;
DateTime StartTimeGMT;
DateTime StartTimeLocal;
Boolean StillRunning;
String UserName;
};
The SMS_G_System_SoftwareUsageData class does not define any methods.
- CompanyName
Data type: String
Access type: Read/Write
Qualifiers: None
Name of the company that made the file, taken from the Company property of the file version resources.
- EndNotCaptured
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true if the metering agent could not capture the actual end time of the process.
- EndTimeGMT
Data type: DateTime
Access type: Read/Write
Qualifiers: [key]
The date and time, in Universal Coordinated Time (UTC), when the process stopped running, if StillRunning is false. If it is true, EndTimeGMT indicates the time when the data was reported.
- EndTimeLocal
Data type: DateTime
Access type: Read/Write
Qualifiers: None
The date and time, in the local time zone of the client, when the process stopped running, if StillRunning is false. If it is true, EndTimeLocal indicates the time when the data was reported.
- FileDescription
Data type: String
Access type: Read/Write
Qualifiers: None
Description of the metered file, taken from the files version resources.
- FileID
Data type: SInt64
Access type: Read/Write
Qualifiers: None
ID of the file that was metered. To find the file information, the application matches this property to the ID in SMS_ProductFileInfo Server WMI Class. To find the rules that caused the file to be metered, the application matches FileID to the ID in SMS_MeteredFiles Server WMI Class.
- FileName
Data type: String
Access type: Read/Write
Qualifiers: None
File name of the metered file if the metering rule matched the file name. If it did not match, but the OriginalFileName property of the rule matched the original file name in the files version resources, this property represents the original file name.
- FileSize
Data type: UInt32
Access type: Read/Write
Qualifiers: None
Size of the metered file.
- FileVersion
Data type: String
Access type: Read/Write
Qualifiers: None
File version of the metered file, taken from the file version resources.
- InTSSession
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true if the file was used in a Terminal Server session. Set this property to false if the file was used in a console session.
- MeterDataID
Data type: String
Access type: Read/Write
Qualifiers:
[key]
Unique ID of a particular instance of a running process on a computer. A record with this ID is created every time the client reports on the same instance of a running program.
- ProductLanguage
Data type: UInt32
Access type: Read/Write
Qualifiers: [Subtype("Locale Id")]
Language ID of the metered file, taken from the file version resources.
- ProductName
Data type: String
Access type: Read/Write
Qualifiers: None
Product name of the metered file, taken from the file version resources. This is not the product name of the rule that caused the file to be metered.
- ProductVersion
Data type: String
Access type: Read/Write
Qualifiers: None
Product version of the metered file, taken from the file version resources.
- ResourceID
Data type: UInt32
Access type: Read/Write
Qualifiers: [key]
See SMS_G_System Server WMI Class.
For this class, this property represents the ID of the computer that executed the metered program. To find the computer information, your application finds the record with the same resource ID in the SMS_R_System Server WMI Class class.
- StartNotCaptured
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true if the metering agent could not capture the actual start time of the process.
- StartTimeGMT
Data type: DateTime
Access type: Read/Write
Qualifiers: None
The date and time, in Universal Coordinated Time (UTC), when the program started.
- StartTimeLocal
Data type: DateTime
Access type: Read/Write
Qualifiers: None
The date and time, in the local time zone of the client, when the program started.
- StillRunning
Data type: Boolean
Access type: Read/Write
Qualifiers: None
true if the program is still running. Set this property to false if EndTime represents the actual end time of the metered program.
- UserName
Data type: String
Access type: Read/Write
Qualifiers: None
Fully qualified user name of the user of the metered application.
There are no special class qualifiers for this class. For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.
This class counts the number of distinct users and computers that used a metered file during a particular interval on a particular site.
Requirements
For more information, see Configuration Manager Server Runtime Requirements.
For more information, see Configuration Manager Server Development Requirements.