Converged Traffic Test
Note This content applies to the Windows Logo Kit (WLK). For the latest information using the new Windows Hardware Certification Kit (HCK), see Windows HCK User's Guide on the Windows Hardware Dev Center.
Type: Automated test
Overview
The Converged Traffic test ensures that the test adapter supports concurrent network and disk input/output (I/O).
Details
Note This content applies to the Windows Logo Kit (WLK). For the latest information using the new Windows Hardware Certification Kit (HCK), see Windows HCK User's Guide on the Windows Hardware Dev Center.
The Converged Traffic test runs the Disk Stress test against the storage array attached to the Fibre Channel over Ethernet (FCoE) adapter while simultaneously running NTttcp to stress network traffic through the same FCoE adapter. For additional NTttcp details, consult the NTttcp whitepaper available from Windows Hardware Developer Central (WHDC). For Disk Stress details, please see Disk Stress.
Run time: 8 hours
Log file: DiskIO.wtl and Ntttcps.txt
System restart required: No
Test category: Storage Adapter or Controller
Supported operating systems for logo or signature testing:
Windows 7
Windows Server 2008 R2
Windows Vista
Windows Server 2008
Windows Server 2003
Program: Diskio.exe and Ntttcp.exe
Requirements
Software Requirements
The test tool requires the following software:
Supported operating system (see list above)
Software components included with the device that is being tested
Hardware Requirements
The test tool requires the following hardware:
Two FCoE adapters to be tested
Two computers that meet the minimum software requirements
Fibre Channel (FC) storage array with a minimum of 20 GB available
Processor
x86
x64
Running Boot Test
To schedule the Converged Traffic test in Driver Test Manager (DTM), you must first select a secondary machine to be the receiver of network I/O. You must then right-click the job and click Edit Parameters to configure the ReceiverIPAddress. The ReceiverIPAddress should correspond to an FCoE network port on the secondary machine. It should also be reachable from the primary test machine via a network port on the same FCoE adapter that has a storage array attached.
Code Tour
File Manifest
File | Location |
---|---|
DiskIO.exe |
[testbinroot]\nttest\driverstest\storage\ WDK\ |
NTttcp.exe |
[OSBinRoot]\netio\tcp\ |
Build date: 9/14/2012