Interchange control number sequence exhausted for Partner and TPA
Details
Field | Error Details |
---|---|
Product Name | BizTalk Server |
Product Version | 3.9 |
Event ID | - |
Event Source | BizTalk Server EDI |
Component | EDI Engine |
Symbolic Name | EdiControlNumberExhaustedForParty |
Message Text | Interchange control number sequence exhausted for Partner '{1}' for the TPA '{2}'. Reset the sequence in {2} - EDI Properties using BizTalk Server Administration. |
Explanation
This Error/Warning/Information event indicates BizTalk Server was not able to process the document because the Interchange control range has been used up for the agreement in {2}.
User Action
To resolve this error, please tick the checkbox to reset the control number for the {2} agreement or increase the control number range or hit the reset button against the control number range specification in the agreement.
Feedback
https://aka.ms/ContentUserFeedback.
Coming soon: Throughout 2024 we will be phasing out GitHub Issues as the feedback mechanism for content and replacing it with a new feedback system. For more information see:Submit and view feedback for