3.1.4.1.25 RpcAsyncResetPrinter (Opnum 69)

RpcAsyncResetPrinter resets the data type and device mode (For more information, see [DEVMODE]) values to use for printing documents submitted by the RpcAsyncStartDocPrinter method (section 3.1.4.8.1).

The counterpart of this method in the Print System Remote Protocol is RpcResetPrinter. All parameters not defined below are specified in [MS-RPRN] section 3.1.4.2.13.

 DWORD RpcAsyncResetPrinter(
   [in] PRINTER_HANDLE hPrinter,
   [in, string, unique] wchar_t* pDatatype,
   [in] DEVMODE_CONTAINER* pDevModeContainer
 );

hPrinter: A handle to a printer object that has been opened using either RpcAsyncOpenPrinter (section 3.1.4.1.1) or RpcAsyncAddPrinter (section 3.1.4.1.2).

Return Values: This method returns zero to indicate successful completion or a nonzero Win32 error code ([MS-ERREF] section 2.2) to indicate failure. The client MUST treat any nonzero return value as a fatal error.

Exceptions Thrown: This method MUST NOT throw any exceptions other than those that are thrown by the underlying RPC protocol [MS-RPCE].

This method MUST adhere to the parameter validation, processing, and response requirements that are specified in [MS-RPRN] section 3.1.4.2.13.