Preparing for Unclassified Signature Testing

Before running the tests, you must configure at least one client system and install the operating system. This section summarizes the related procedures.

Device and Driver Installation

Install your driver and device on at least one client computer system.

DTM Client Software Installation

Install Driver Test Manager (DTM) client software. After DTM Client is installed, open DTM Studio and locate the new client in the default machine pool.

Create a Machine Pool

If a machine pool has not already been created, perform the following steps to create one.

  1. Right-click the ‘$’ in the left-hand Machine Pool window, and click Add Machine Pool.
  2. In the Add Machine Pool dialog box, type a name for the machine pool, and click OK.

Add the newly installed client to the machine pool by dragging and dropping it from the Default Pool window to the newly created machine pool.

Make the client ready for scheduling

  1. In the machine pool to which you added the newly installed client, right-click the client computer in the Machines windows, click Change Status, then click Reset.

    The Unclassified Master Config Job will automatically schedule and run on the client computer. When the job has completed, the client is ready to begin an Unclassified submission.

  2. Repeat the preceding step for each client in the machine pool.

Send feedback on this topic
Built on December 10, 2009