2.2.5.5.2 Common Language Runtime (CLR) Instances

The following data type definition stream is used for UDT_INFO in TYPE_INFO. This data type was introduced in TDS 7.2.

 DB_NAME                 =   B_VARCHAR  ; database name of the UDT
 SCHEMA_NAME             =   B_VARCHAR  ; schema name of the UDT
 TYPE_NAME               =   B_VARCHAR  ; type name of the UDT
  
 MAX_BYTE_SIZE           =   USHORT     ; max length in bytes
 ASSEMBLY_QUALIFIED_NAME =   US_VARCHAR ; name of the CLR assembly
  
 UDT_METADATA            =   ASSEMBLY_QUALIFIED_NAME
  
 UDT_INFO_IN_COLMETADATA =   MAX_BYTE_SIZE
                             DB_NAME
                             SCHEMA_NAME
                             TYPE_NAME
                             UDT_METADATA
  
 UDT_INFO_IN_RPC  =   DB_NAME       ; database name of the UDT
                      SCHEMA_NAME   ; schema name of the UDT
                      TYPE_NAME     ; type name of the UDT
  
 UDT_INFO            = UDT_INFO_IN_COLMETADATA        ;when sent as part of COLMETADATA
                       /
                       UDT_INFO_IN_RPC                ;when sent as part of RPC call

MAX_BYTE_SIZE is only sent from the server to the client in COLMETADATA and is an unsigned short with a value within the range 1 to 8000 or 0xFFFF. The value 0xFFFF signifies the maximum LOB size indicating a UDT with a maximum size greater than 8000 bytes (also referred to as a Large UDT; introduced in TDS 7.3). MAX_BYTE_SIZE is not sent to the server as part of RPC calls.

Note UserType in the COLMETADATA stream is always 0x0000 for UDTs. The actual data value format associated with a UDT data type definition stream is specified in [MS-SSCLRT].