This content is no longer actively maintained. It is provided as is, for anyone who may still be using these technologies, with no warranties or claims of accuracy with regard to the most recent product version or service release.

Specifies a subnet that is statically defined for Quality of Experience (QoE) reporting and monitoring purposes.

The properties in the MSFT_SIPQMSStaticSubnet class do not map directly to the Office Communications Server 2007 R2 Administration Tool.

This class is populated when MMC imports locations.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

class MSFT_SIPQMSStaticSubnet
{
  [key] string Backend;
  [key] string InstanceID;
  string LocationID;
  sint32 Subnet;
  sint32 SubnetMask;
};

Methods

This class does not define any methods.

Properties

The MSFT_SIPQMSStaticSubnet class has the following properties.

Backend

Data type: [key] string

Access type: Read-only

Required: Identifies the instance of SQL Server that manages the database for Monitoring Server.

This property specifies the database server using the following format:

computername\instancename

The value computername identifies either the FQDN or the NetBIOS name of the host computer for SQL Server and instancename identifies a named instance of SQL Server on the host computer.

The maximum length of the string is 273 characters.

InstanceID

Data type: [key] string

Access type: Read-only

Required. A GUID value that uniquely identifies an instance of this class.

The GUID must be encapsulated between the "{" and "}" braces; for example: "{01234567-0123-4567-89AB-CDEF01234567}".

LocationID

Data type: string

Access type: Read/Write

Required. Identifies a location (MSFT_SIPQMSStaticLocation.InstanceID).

Subnet

Data type: sint32

Access type: Read/Write

Required. The subnet for QoE reporting and monitoring.

SubnetMask

Data type: sint32

Access type: Read/Write

Required. The subnet mask for QoE reporting and monitoring.

Remarks

This class gets and sets information at the following level: SQL.

Instances of this class support the following interface methods:

  • Provider::DeleteInstance();

  • Provider::GetObject();

  • Provider::PutInstance();

    Where PutInstance() supports the following flags:

    • WBEM_FLAG_CREATE_ONLY

    • WBEM_FLAG_UPDATE_ONLY

    • WBEM_FLAG_CREATE_OR_UPDATE

Requirements

Server: Installed on computers serving the following role: Monitoring Server.

Namespace: Defined in \root\cimv2.