class 	MSFT_SIPPoolSetting
{
  string BackEndDBPath;
  string DefaultLocationProfile;
  string DomainFQDN;
  [key] string InstanceID;
  uint32 MajorVersion;
  string[] MCUFactoryList;
  uint32 MinorVersion;
  string PoolDisplayName;
  string PoolDN;
  string PoolFQDN;
  string[] PoolMemberList;
  string PoolType;
  boolean SupportIMPresence;
  boolean SupportMeeting;
  string TrustedMRASServer;
  string TrustedQoSServer;
  string[] WebComponentsServerList;
};

Methods

This class does not define any methods.

Properties

The MSFT_SIPPoolSetting class has the following properties.

BackEndDBPath

Data type: string

Access type: Read-only

Required. The computer name (either the FQDN or NetBIOS name) and SQL Server instance name of the Office Communications Server 2007, Back-End Database.

The value generated as part of the creation of a pool. The value of this property is not case-sensitive.

DefaultLocationProfile

Data type: string

Access type: Read/Write

Optional. The distinguished name of the Location profile for this pool.

The value of this property is not case-sensitive.

DomainFQDN

Data type: string

Access type: Read-only

Optional. The fully qualified domain name (FQDN) of the domain.

The value must be an FQDN. An IP address is not allowed.

InstanceID

Data type: [key] string

Access type: Read-only

Required. A GUID value that uniquely identifies an instance of this class.

The GUID must be encapsulated between the "{" and "}" braces; for example: "{01234567-0123-4567-89AB-CDEF01234567}".

MajorVersion

Data type: uint32

Access type: Read-only

Required. The major Office Communications Server version number.

Value

Description

2

Office Live Communications Server 2005

3

Office Communications Server 2007

The default value is 3.

MCUFactoryList

Data type: string[]

Access type: Read-only

Optional. A list of the distinguished names of the MCU Factories that this pool supports.

The value of this property is not case-sensitive.

MinorVersion

Data type: uint32

Access type: Read-only

Required. The minor Office Communications Server version number.

Value

Description

0

Original release to market

1

Service Pack 1 release

The default value is 0.

PoolDisplayName

Data type: string

Access type: Read-only

Required. The name of the pool as it appears in the Microsoft Management Console.

The value of this property is not case-sensitive.

PoolDN

Data type: string

Access type: Read-only

Required. The distinguished name of the pool object in Active Directory.

The value of this property is not case-sensitive.

PoolFQDN

Data type: string

Access type: Read-only

Required. The fully qualified domain name (FQDN) of the pool.

The certificate for the pool must match this name. The value must be an FQDN. An IP address is not allowed.

PoolMemberList

Data type: string[]

Access type: Read-only

Optional. A list of the fully qualified domain name(s) (FQDN) of servers belonging to an Enterprise Edition pool or Standard Edition pool. In the case of a Standard Edition pool, there will be only one server in the list.

The value of this property is not case-sensitive.

PoolType

Data type: string

Access type: Read-only

Required. Specifies whether the pool is an Enterprise Edition pool or a Standard Edition pool.

The value of this property is not case-sensitive.

Value

Description

"HomeServerPool"

A Standard Edition pool.

"FEPool"

An Enterprise Edition pool.

SupportIMPresence

Data type: boolean

Access type: Read-only

Reserved. Do not use.

SupportMeeting

Data type: boolean

Access type: Read-only

Reserved. Do not use.

TrustedMRASServer

Data type: string

Access type: Read/Write

Optional. The distinguished name for the Trusted MRAS Server that serves this pool.

The value of this property is not case-sensitive.

TrustedQoSServer

Data type: string

Access type: Read/Write

Optional. The distinguished name for the QoS Server that serves this pool.

The value of this property is not case-sensitive.

WebComponentsServerList

Data type: string[]

Access type: Read-only

Optional. A list of the distinguished names of the Web servers that this pool supports.

The value of this property is not case-sensitive.

Remarks

This class gets and sets information at the following level(s): AD.

Instances of this class support the following interface methods:

Provider::EnumerateInstances(); Provider::GetObject(); Provider::PutInstance();

Where PutInstance() supports the following flag(s):

WBEM_FLAG_UPDATE_ONLY

Requirements

Server: Installed on computers serving the following role(s): Administrative Tools Server, Audio/Video Conferencing Server, Front End Server, Proxy Server, Web Components Server, Web Conferencing Server.Namespace: Defined in \root\cimv2.


Reference

[<LinkCreatedDuringXmlConversion>]

Concepts

Show:
© 2015 Microsoft