3.3.4 Message Processing Events and Sequencing Rules
This protocol MUST indicate to the RPC runtime that it is to perform a strict NDR data consistency check at target level 5.0 ([MS-RPCE] section 3.1.1.5.3).
Remote shutdown communication between a client and a server occurs through RPC calls.
The WindowsShutdown interface includes the following methods.<13>
Methods in RPC Opnum Order
Method |
Description |
---|---|
The WsdrInitiateShutdown method is used to initiate the shutdown of the remote computer. Opnum: 0 |
|
The WsdrAbortShutdown method is used to abort the shutdown of the remote computer within the waiting period. Opnum: 1 |
Note Exceptions MUST NOT be thrown, except those thrown by the underlying RPC protocol [MS-RPCE], unless specified otherwise.