SMS_Report Server WMI Class
Updated: October 28, 2009
Applies To: System Center Configuration Manager 2007, System Center Configuration Manager 2007 R2, System Center Configuration Manager 2007 R3, System Center Configuration Manager 2007 SP1, System Center Configuration Manager 2007 SP2
The SMS_Report Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a fully defined report that can be run by Configuration Manager Reports.
The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.
Class SMS_Report : SMS_BaseClass
{
String Category;
String Comment;
UInt32 DrillThroughColumns[];
UInt32 DrillThroughReportID;
ref:SMS_Report DrillThroughReportPath;
String DrillThroughURL;
String GraphCaption;
UInt32 GraphType;
UInt32 GraphXCol;
UInt32 GraphYCol;
Boolean MachineDetail;
Boolean MachineSource;
String Name;
UInt32 NumPrompts;
UInt32 RefreshInterval;
String ReportGUID;
UInt32 ReportID;
SMS_ReportParameter ReportParams[];
String SecurityKey;
String SQLQuery;
Boolean StatusMessageDetailSource;
Boolean UnicodeData;
String XColLabel;
String YColLabel;
};
The following table shows the methods in SMS_Report.
| Method | Description |
|---|---|
|
Gets report point information. |
|
|
Verifies that a report query is a valid SQL statement and performs the same level of validation that occurs when the report is saved. |
- Category
- Data type: String Access type: Read/Write Qualifiers: None Category to be used in the Configuration Manager console to filter the list of reports and to provide a report hierarchy. The default value is "".
- Comment
- Data type: String Access type: Read/Write Qualifiers: None Further description of the report to be displayed on the property page for the report in the Configuration Manager console.
- DrillThroughColumns
- Data type: UInt32 Array Access type: Read/Write Qualifiers: None Integers indicating the columns to use as the parameters of the destination report when drilling through on a particular row. If this property is not applicable, set it to null or an empty array.
- DrillThroughReportID
- Data type: UInt32 Access type: Read/Write Qualifiers: None Report ID to link to each row of the report. Selected columns from the originating report are used as parameters to the destination report. Set this property to null if there is no drill-through destination for the report. This property can be set to a report object path to support references to other reports in the same MOF file as the originating report.
- DrillThroughReportPath
- Data type: SMS_Report REF Access type: Read Only Qualifiers: [lazy] Relative path of the WMI object representing the destination report to which the originating report will drill through. When defining multiple reports in a MOF file that link together, set this property to the path alias from the previously defined drill-through report.
- DrillThroughURL
- Data type: String Access type: Read/Write Qualifiers: None The URL of the drill-through report.
- GraphCaption
- Data type: String Access type: Read/Write Qualifiers: None Caption for the report graph. If there is no graph, set this property to null.
- GraphType
- Data type: UInt32 Access type: Read/Write Qualifiers: None Type of report graph. Set this property to null if no graph is available.
- GraphXCol
- Data type: UInt32 Access type: Read/Write Qualifiers: None Column number to use for the X axis of the graph. Set this property to null if it is not applicable.
- GraphYCol
- Data type: UInt32 Access type: Read/Write Qualifiers: None Column number to use for the Y axis of the graph. Set this property to null if it is not applicable.
- MachineDetail
- Data type: Boolean Access type: Read/Write Qualifiers: Nonetrue if the report is a computer detail report, having one parameter that represents the Name0 column of the report. The default value is false.
- MachineSource
- Data type: Boolean Access type: Read/Write Qualifiers: Nonetrue if this report drills through to the computer details page. The DrillThroughColumns property should contain a single index representing the Name0 column of the report. The default value is false.
- Name
- Data type: String Access type: Read/Write Qualifiers: None Report name to display in the Configuration Manager console and on the report itself.
- NumPrompts
- Data type: UInt32 Access type: Read/Write Qualifiers: None The number of report prompts allowed in the console.
- RefreshInterval
- Data type: UInt32 Access type: Read/Write Qualifiers: [Range("0-60")] The interval, in seconds, that should elapse before the report is automatically rerun and the page is refreshed. Possible values are 0 (default) through 60. Set this property to 0 if the page should not be automatically refreshed.
- ReportGUID
- Data type: String Access type: Read/Write Qualifiers: [unique] GUID for the report.
- ReportID
- Data type: UInt32 Access type: Read/Write Qualifiers: [key] Unique automatically generated number that identifies the report.
- ReportParams
- Data type: SMS_ReportParameter Array Access type: Read/Write Qualifiers: [lazy]SMS_ReportParameter Server WMI Class objects that define the user-supplied parameters to the report. Set this property to null or an empty array if there are no parameters.
- SecurityKey
- Data type: String Access type: Read/Write Qualifiers: [unique] Unique automatically generated key used as the security identifier for the SMS_UserInstancePermissions Server WMI Class class.
- SQLQuery
- Data type: String Access type: Read/Write Qualifiers: [lazy, large] Text of the SQL query that produces the result set of the report.
- StatusMessageDetailSource
- Data type: Boolean Access type: Read/Write Qualifiers: Nonetrue if the source of the status message is detailed. The default value is false.
- UnicodeData
- Data type: Boolean Access type: Read/Write Qualifiers: Nonetrue if the report includes Unicode data. The default value is false.
- XColLabel
- Data type: String Access type: Read/Write Qualifiers: None Caption for the X axis of the graph. Set this property to null if it is not applicable.
- YColLabel
- Data type: String Access type: Read/Write Qualifiers: None Caption for the Y axis of the graph. Set this property to null if it is not applicable.
Class qualifiers for this class include:
-
Secured
For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.
Runtime Requirements
For more information, see Configuration Manager Server Runtime Requirements.
Development Requirements
For more information, see Configuration Manager Server Development Requirements.