The interchange had a structural error in-before the first functional group

Details

Field Error Details
Product Name BizTalk Server
Product Version 3.9
Event ID -
Event Source BizTalk Server EDI
Component EDI Engine
Symbolic Name X12InterchangeStructuralErrorBefore1stGroup
Message Text The interchange with id '{0}', with sender id '{1}', receiver id '{2}' had structural error in/before the first functional group

Explanation

This Error/Warning/Information event indicates that the receive pipeline could not process the incoming interchange, for one of the following reasons:

  • A structural error occurred in either the ISA and IEA segments or the first functional group of the interchange, so the interchange did not conform to the applicable schema.

  • The X12ServiceSchema (in BaseArtifacts.dll) was not deployed.

User Action

To resolve this error, do one of the following:

  • Have the sender of the interchange change the ISA and/or IEA segments or the first functional group so that it conforms to the applicable schema, and then resend the interchange.

  • Ensure that BaseArtifacts.dll includes the X12ServiceSchema and is deployed. You can do so by opening the BizTalk Server Administration Console, opening the BizTalk EDI Application node and the Schemas node, and verifying that X12ServiceSchema is listed.