Win32_SystemSlot class

The Win32_SystemSlot WMI class represents physical connection points including ports, motherboard slots and peripherals, and proprietary connection points.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

[Dynamic, Provider("CIMWin32"), UUID("{FAF76B91-798C-11D2-AAD1-006008C78BC7}"), AMENDMENT]
class Win32_SystemSlot : CIM_Slot
{
  uint32   BusNumber;
  string   Caption;
  string   ConnectorPinout;
  uint16   ConnectorType[];
  string   CreationClassName;
  uint16   CurrentUsage;
  string   Description;
  uint32   DeviceNumber;
  uint32   FunctionNumber;
  real32   HeightAllowed;
  datetime InstallDate;
  real32   LengthAllowed;
  string   Manufacturer;
  uint16   MaxDataWidth;
  string   Model;
  string   Name;
  uint16   Number;
  string   OtherIdentifyingInfo;
  string   PartNumber;
  boolean  PMESignal;
  boolean  PoweredOn;
  string   PurposeDescription;
  uint32   SegmentGroupNumber;
  string   SerialNumber;
  boolean  Shared;
  string   SKU;
  string   SlotDesignation;
  boolean  SpecialPurpose;
  string   Status;
  boolean  SupportsHotPlug;
  string   Tag;
  uint32   ThermalRating;
  uint16   VccMixedVoltageSupport[];
  string   Version;
  uint16   VppMixedVoltageSupport[];
};

Members

The Win32_SystemSlot class has these types of members:

Properties

The Win32_SystemSlot class has these properties.

BusNumber
Data type: uint32
Access type: Read-only
Qualifiers: MappingStrings ("SMBIOS|Type 9|Bus Number")

SMBIOS Bus Number.

Windows Server 2012 R2, Windows 8.1, Windows Server 2012, Windows 8, Windows Server 2008 R2, Windows 7, Windows Server 2008, Windows Vista, and Windows Server 2003:  This property is not supported.

Caption
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64 (0x40))

Short description of an object—a one-line string. This property is inherited from CIM_ManagedSystemElement.

ConnectorPinout
Data type: string
Access type: Read-only

Free-form string that describes the pin configuration and signal usage of a physical connector. This property is inherited from CIM_PhysicalConnector.

ConnectorType
Data type: uint16 array
Access type: Read-only
Qualifiers: Override ("ConnectorType") , MappingStrings ("SMBIOS|Type 9|Slot Type")

Array of physical attributes of the connector that this slot uses. This property is inherited from CIM_PhysicalConnector.

ValueMeaning
Unknown
0
Other
1
Male
2
Female
3
Shielded
4
Unshielded
5
SCSI (A) High-Density (50 pins)
6
SCSI (A) Low-Density (50 pins)
7
SCSI (P) High-Density (68 pins)
8
SCSI SCA-I (80 pins)
9
SCSI SCA-II (80 pins)
10
SCSI Fibre Channel (DB-9, Copper)
11
SCSI Fibre Channel (Fibre)
12
SCSI Fibre Channel SCA-II (40 pins)
13
SCSI Fibre Channel SCA-II (20 pins)
14
SCSI Fibre Channel BNC
15
ATA 3-1/2 Inch (40 pins)
16
ATA 2-1/2 Inch (44 pins)
17
ATA-2
18
ATA-3
19
ATA/66
20
DB-9
21
DB-15
22
DB-25
23
DB-36
24
RS-232C
25
RS-422
26
RS-423
27
RS-485
28
RS-449
29
V.35
30
X.21
31
IEEE-488
32
AUI
33
UTP Category 3
34
UTP Category 4
35
UTP Category 5
36
BNC
37
RJ11
38
RJ45
39
Fiber MIC
40
Apple AUI
41
Apple GeoPort
42
PCI
43
ISA
44
EISA
45
VESA
46
PCMCIA
47
PCMCIA Type I
48
PCMCIA Type II
49
PCMCIA Type III
50
ZV Port
51
CardBus
52
USB
53
IEEE 1394
54
HIPPI
55
HSSDC (6 pins)
56
GBIC
57
DIN
58
Mini-DIN
59
Micro-DIN
60
PS/2
61
Infrared
62
HP-HIL
63
Access.bus
64
NuBus
65
Centronics
66
Mini-Centronics
67
Mini-Centronics Type-14
68
Mini-Centronics Type-20
69
Mini-Centronics Type-26
70
Bus Mouse
71
ADB
72
AGP
73
VME Bus
74
VME64
75
Proprietary
76
Proprietary Processor Card Slot
77
Proprietary Memory Card Slot
78
Proprietary I/O Riser Slot
79
PCI-66MHZ
80
AGP2X
81
AGP4X
82
PC-98
83
PC-98-Hireso
84
PC-H98
85
PC-98Note
86
PC-98Full
87
PCI-X
88
Sbus IEEE 1396-1993 32 bit
89

SSA SCSI

Sbus IEEE 1396-1993 64 bit
90

Circular

MCA
91

On-Board IDE Connector

GIO
92

On-Board Floppy Connector

XIO
93

9 Pin Dual Inline

HIO
94

25 Pin Dual Inline

NGIO
95

50 Pin Dual Inline

PMC
96

68 Pin Dual Inline

Future I/O
97

On-Board Sound Connector

InfiniBand
98

Mini-Jack

AGP8X
99

PCI-X

PCI-E
100

Sbus IEEE 1396-1993 32 Bit

101

Sbus IEEE 1396-1993 64 Bit

102

MCA

103

GIO

104

XIO

105

HIO

106

NGIO

107

PMC

108

MTRJ

109

VF-45

110

Future I/O

111

SC

112

SG

113

Electrical

114

Optical

115

Ribbon

116

GLM

117

1x9

118

Mini SG

119

LC

120

HSSC

121

VHDCI Shielded (68 pins)

122

InfiniBand

123

AGP8X

124

PCI-E

 

CreationClassName
Data type: string
Access type: Read-only
Qualifiers: Key, MaxLen (256 (0x100))

Name of the first concrete class that appears in the inheritance chain used in the creation of an instance. When used with the other key properties of a class, this property allows all instances of this class and its subclasses to be identified uniquely. This property is inherited from CIM_PhysicalElement.

CurrentUsage
Data type: uint16
Access type: Read-only
Qualifiers: MappingStrings ("SMBIOS|Type 9|Current Usage")

Status of system slot use.

Reserved (0)
Other (1)
Unknown (2)
Available (3)
In use (4)
Description
Data type: string
Access type: Read-only

Description of the object. This property is inherited from CIM_ManagedSystemElement.

DeviceNumber
Data type: uint32
Access type: Read-only
Qualifiers: MappingStrings ("SMBIOS|Type 9|Device Number")

SMBIOS Device Number.

Windows Server 2012 R2, Windows 8.1, Windows Server 2012, Windows 8, Windows Server 2008 R2, Windows 7, Windows Server 2008, Windows Vista, and Windows Server 2003:  This property is not supported.

FunctionNumber
Data type: uint32
Access type: Read-only
Qualifiers: MappingStrings ("SMBIOS|Type 9|Function Number")

SMBIOS Function Number.

Windows Server 2012 R2, Windows 8.1, Windows Server 2012, Windows 8, Windows Server 2008 R2, Windows 7, Windows Server 2008, Windows Vista, and Windows Server 2003:  This property is not supported.

HeightAllowed
Data type: real32
Access type: Read-only

Maximum height of an adapter card that can be inserted into the slot—in inches. This property is inherited from CIM_Slot.

InstallDate
Data type: datetime
Access type: Read-only

Date and time the object is installed. This property does not need a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.

LengthAllowed
Data type: real32
Access type: Read-only

Maximum length of an adapter card that can be inserted into the slot—in inches. This property is inherited from CIM_Slot.

Manufacturer
Data type: string
Access type: Read-only
Qualifiers: MaxLen (256 (0x100))

Name of the organization that produces the physical element. This property is inherited from CIM_PhysicalElement.

MaxDataWidth
Data type: uint16
Access type: Read-only
Qualifiers: Override ("MaxDataWidth") , MappingStrings ("MIF.DMTF|System Slot|004.3") , Units ("bits")

Maximum bus width of adapter cards that can be inserted into this slot—in bits. This can be one of the following values. This property is inherited from CIM_Slot.

ValueMeaning
8
0

Maximum data width (bits): 8

16
1

Maximum data width (bits): 16

32
2

Maximum data width (bits): 32

64
3

Maximum data width (bits): 64

128
4

Maximum data width (bits): 128

 

Model
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64 (0x40))

Name for the physical element. This property is inherited from CIM_PhysicalElement.

Name
Data type: string
Access type: Read-only

Label for the object. When subclassed, this property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement.

Number
Data type: uint16
Access type: Read-only

Physical slot number that can be used as an index into a system slot table, whether or not that slot is physically empty. This property is inherited from CIM_Slot.

OtherIdentifyingInfo
Data type: string
Access type: Read-only

Additional data (that is, more than the asset tag information), that can be used to identify a physical element. One example is bar code data associated with an element that also has an asset tag. Note that if only bar code data is available, and it is unique or can be used as an element key, this property is NULL, and the bar code data is used as the class key in the Tag property. This property is inherited from CIM_PhysicalElement.

PartNumber
Data type: string
Access type: Read-only
Qualifiers: MaxLen (256 (0x100))

Part number that the producer or manufacturer assigns to the physical element. This property is inherited from CIM_PhysicalElement.

PMESignal
Data type: boolean
Access type: Read-only
Qualifiers: MappingStrings ("SMBIOS|Type 9|Slot Characteristics 2")

If TRUE, the PCI bus Power Management Enabled (PME) signal is supported by this slot.

PoweredOn
Data type: boolean
Access type: Read-only

If TRUE, the physical element is powered on. This property is inherited from CIM_PhysicalElement.

PurposeDescription
Data type: string
Access type: Read-only

Free-form string that describes how this slot is physically unique and may hold special types of hardware. This property only has meaning when the corresponding property SpecialPurpose is TRUE. This property is inherited from CIM_Slot.

SegmentGroupNumber
Data type: uint32
Access type: Read-only
Qualifiers: MappingStrings ("SMBIOS|Type 9|Segment Group Number")

SMBIOS Segment Group Number.

Windows Server 2012 R2, Windows 8.1, Windows Server 2012, Windows 8, Windows Server 2008 R2, Windows 7, Windows Server 2008, Windows Vista, and Windows Server 2003:  This property is not supported.

SerialNumber
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64 (0x40))

Manufacturer-allocated number used to identify the physical element. This property is inherited from CIM_PhysicalElement.

Shared
Data type: boolean
Access type: Read-only
Qualifiers: MappingStrings ("SMBIOS|Type 9|Slot Characteristics 1")

If TRUE, two or more slots share a location on the baseboard, such as a PCI/EISA shared slot.

SKU
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64 (0x40))

Stockkeeping unit number for the physical element. This property is inherited from CIM_PhysicalElement.

SlotDesignation
Data type: string
Access type: Read-only
Qualifiers: MappingStrings ("SMBIOS|Type 9|Slot Designation")

SMBIOS string that identifies the system slot designation of the slot on the motherboard.

Example: "PCI-1"

SpecialPurpose
Data type: boolean
Access type: Read-only

If TRUE, this slot is physically unique and may hold special types of hardware, such as a graphics processor slot. If TRUE, then PurposeDescription should specify the nature of the uniqueness or purpose of the slot. This property is inherited from CIM_Slot.

Status
Data type: string
Access type: Read-only
Qualifiers: MaxLen (10 (0xA))

Current status of the object. Various operational and nonoperational statuses can be defined. Operational statuses include: "OK", "Degraded", and "Pred Fail" (an element, such as a SMART-enabled hard disk drive, may be functioning properly but predicting a failure in the near future). Nonoperational statuses include: "Error", "Starting", "Stopping", and "Service". The latter, "Service", could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is online, yet the managed element is neither "OK" nor in one of the other states. This property is inherited from CIM_ManagedSystemElement.

The values are:

"OK"
"Error"
"Degraded"
"Unknown"
"Pred Fail"
"Starting"
"Stopping"
"Service"
"Stressed"
"NonRecover"
"No Contact"
"Lost Comm"
SupportsHotPlug
Data type: boolean
Access type: Read-only

If TRUE, the slot supports hot-plugging of adapter cards. This property is inherited from CIM_Slot.

Tag
Data type: string
Access type: Read-only
Qualifiers: Key, MaxLen (256) , Override ("Tag") , MappingStrings ("WMI")

System slot represented by an instance of this class. This property is inherited from CIM_PhysicalElement.

Example: "System Slot 1"

ThermalRating
Data type: uint32
Access type: Read-only

Maximum thermal dissipation of the slot in milliwatts. This property is inherited from CIM_Slot.

VccMixedVoltageSupport
Data type: uint16 array
Access type: Read-only

Array of enumerated integers indicating the Vcc voltage supported by this slot. This property is inherited from CIM_Slot.

ValueMeaning
0 (0x0)

Unknown

1 (0x1)

Other

2 (0x2)

3.3V

3 (0x3)

5V

 

Version
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64 (0x40))

Version of the physical element. This property is inherited from CIM_PhysicalElement.

VppMixedVoltageSupport
Data type: uint16 array
Access type: Read-only

Array of enumerated integers indicating the Vpp voltage supported by this slot. This property is inherited from CIM_Slot.

ValueMeaning
0 (0x0)

Unknown

1 (0x1)

Other

2 (0x2)

3.3V

3 (0x3)

5V

4 (0x4)

12V

 

Remarks

The Win32_SystemSlot class is derived from CIM_Slot.

Requirements

Minimum supported client

Windows Vista

Minimum supported server

Windows Server 2003

Namespace

Root\CIMV2

MOF

CIMWin32.mof

DLL

CIMWin32.dll

See also

CIM_Slot
Computer System Hardware Classes

 

 

Show:
© 2015 Microsoft