3.1.4.1.14 RpcAsyncDeletePrinterData (Opnum 30)
RpcAsyncDeletePrinterData deletes a specified value from the configuration of a specified printer.
The counterpart of this method in the Print System Remote Protocol is RpcDeletePrinterData. All parameters not defined below are specified in [MS-RPRN] section 3.1.4.2.17.
-
DWORD RpcAsyncDeletePrinterData( [in] PRINTER_HANDLE hPrinter, [in, string] wchar_t* pValueName );
hPrinter: A handle to a printer object that has been opened using either RpcAsyncOpenPrinter (section 3.1.4.1.1) or RpcAsyncAddPrinter (section 3.1.4.1.2).
Return Values: This method returns zero to indicate successful completion or a nonzero Win32 error code ([MS-ERREF] section 2.2) to indicate failure. The client MUST treat any nonzero return value as a fatal error.
Exceptions Thrown: This method MUST NOT throw any exceptions other than those that are thrown by the underlying RPC protocol [MS-RPCE].
This method MUST adhere to the parameter validation, processing, and response requirements that are specified in [MS-RPRN] section 3.1.4.2.17.