3.1.2.5.1.8 Allocating OXID Entries
When the object exporter contacts the object resolver to allocate an OXID (see section 3.1.1.3), the object resolver MUST allocate an OXID entry as follows:
It MUST allocate an OXID and set in the entry.
It MUST set the RPC binding of the object exporter to NULL.
It MUST set the COMVERSION to that of the object exporter.
It MUST set the authentication level hint to that of the object exporter.