EN
Este contenido no se encuentra disponible en su idioma, pero aquí tiene la versión en inglés.

CIM_PhysicalConnector class

The CIM_PhysicalConnector class represents any physical element that is used to connect to other elements. Any object that can connect and transmit signals or power between two or more physical elements is a descendant (or member) of this class. For example, slots and D-shell connectors are types of physical connectors.

Important  The DMTF (Distributed Management Task Force) CIM (Common Information Model) classes are the parent classes upon which WMI classes are built. WMI currently supports only the CIM 2.x version schemas.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of its inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

class CIM_PhysicalConnector : CIM_PhysicalElement
{
  string   Caption;
  string   ConnectorPinout;
  uint16   ConnectorType[];
  string   CreationClassName;
  string   Description;
  datetime InstallDate;
  string   Manufacturer;
  string   Model;
  string   Name;
  string   OtherIdentifyingInfo;
  string   PartNumber;
  boolean  PoweredOn;
  string   SerialNumber;
  string   SKU;
  string   Status;
  string   Tag;
  string   Version;
};

Members

The CIM_PhysicalConnector class has these types of members:

Properties

The CIM_PhysicalConnector class has these properties.

Caption
Data type: string
Access type: Read-only

Short textual description of the object. This property is inherited from CIM_ManagedSystemElement.

ConnectorPinout
Data type: string
Access type: Read-only

Free-form string that describes the pin configuration and signal use of a physical connector.

ConnectorType
Data type: uint16 array
Access type: Read-only

Type of physical connector. An array is specified to allow the description of combinations of connector information. For example, one array entry could specify RS-232, another DB-25, and a third entry could define the connector as "male".

ValueMeaning
0

Unknown

1

Other

2

Male

3

Female

4

Shielded

5

Unshielded

6

SCSI (A) High-density (50 pins)

7

SCSI (A) Low-density (50 pins)

8

SCSI (P) High-density (68 pins)

9

SCSI SCA-I (80 pins)

10

SCSI SCA-II (80 pins)

11

SCSI Fibre Channel (DB-9, Copper)

12

SCSI Fibre Channel (Fibre)

13

SCSI Fibre Channel SCA-II (40 pins)

14

SCSI Fibre Channel SCA-II (20 pins)

15

SCSI Fibre Channel BNC

16

ATA 3-1/2 Inch (40 pins)

17

ATA 2-1/2 Inch (44 pins)

18

ATA-2

19

ATA-3

20

ATA/66

21

DB-9

22

DB-15

23

DB-25

24

DB-36

25

RS-232C

26

RS-422

27

RS-423

28

RS-485

29

RS-449

30

V.35

31

X.21

32

IEEE-488

33

AUI

34

UTP Category 3

35

UTP Category 4

36

UTP Category 5

37

BNC

38

RJ11

39

RJ45

40

Fiber MIC

41

Apple AUI

42

Apple GeoPort

43

PCI

44

ISA

45

EISA

46

VESA

47

PCMCIA

48

PCMCIA Type I

49

PCMCIA Type II

50

PCMCIA Type III

51

ZV Port

52

CardBus

53

USB

54

IEEE 1394

55

HIPPI

56

HSSDC (6 pins)

57

GBIC

58

DIN

59

Mini-DIN

60

Micro-DIN

61

PS/2

62

Infrared

63

HP-HIL

64

Access.bus

65

NuBus

66

Centronics

67

Mini-Centronics

68

Mini-Centronics Type-14

69

Mini-Centronics Type-20

70

Mini-Centronics Type-26

71

Bus Mouse

72

ADB

73

AGP

74

VME Bus

75

VME64

76

Proprietary

77

Proprietary Processor Card Slot

78

Proprietary Memory Card Slot

79

Proprietary I/O Riser Slot

80

PCI-66MHZ

81

AGP2X

82

AGP4X

83

PC-98

84

PC-98-Hireso

85

PC-H98

86

PC-98Note

87

PC-98Full

88

SSA SCSI

89

Circular

90

On Board IDE Connector

91

On Board Floppy Connector

92

9 Pin Dual Inline

93

25 Pin Dual Inline

94

50 Pin Dual Inline

95

68 Pin Dual Inline

96

On Board Sound Connector

97

Mini-jack

98

PCI-X

99

Sbus IEEE 1396-1993 32 bit

100

Sbus IEEE 1396-1993 64 bit

101

MCA

102

GIO

103

XIO

104

HIO

105

NGIO

106

PMC

107

MTRJ

108

VF-45

109

Future I/O

110

SC

111

SG

112

Electrical

113

Optical

114

Ribbon

115

GLM

116

1x9

117

Mini SG

118

LC

119

HSSC

120

VHDCI Shielded (68 pins)

121

InfiniBand

 

CreationClassName
Data type: string
Access type: Read-only

Name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified. This property is inherited from CIM_PhysicalElement.

Description
Data type: string
Access type: Read-only

Textual description of the object. This property is inherited from CIM_ManagedSystemElement.

InstallDate
Data type: datetime
Access type: Read-only

Date and time the object was installed. This property does not need a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.

Manufacturer
Data type: string
Access type: Read-only

Name of the organization that produced the physical element. For more information, see the Vendor property of CIM_Product. This property is inherited from CIM_PhysicalElement.

Model
Data type: string
Access type: Read-only

Name by which the physical element is generally known. This property is inherited from CIM_PhysicalElement.

Name
Data type: string
Access type: Read-only

Label by which the object is known. When subclassed, this property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement.

OtherIdentifyingInfo
Data type: string
Access type: Read-only

Additional data, beyond asset tag information, that can be used to identify a physical element. One example is bar-code data that is associated with an element, which also has an asset tag. Note that if only bar-code data is available, and is unique and able to be used as an element key, this property would be null and the bar-code data would be used as the class key in the Tag property. This property is inherited from CIM_PhysicalElement.

PartNumber
Data type: string
Access type: Read-only

Part number assigned by the organization responsible for producing or manufacturing the physical element. This property is inherited from CIM_PhysicalElement.

PoweredOn
Data type: boolean
Access type: Read-only

If TRUE, the physical element is powered on; otherwise, it is currently off. This property is inherited from CIM_PhysicalElement.

SerialNumber
Data type: string
Access type: Read-only

Manufacturer-allocated number used to identify the physical element. This property is inherited from CIM_PhysicalElement.

SKU
Data type: string
Access type: Read-only

Stock-keeping unit number for the physical element. This property is inherited from CIM_PhysicalElement.

Status
Data type: string
Access type: Read-only

Current status of the object. This property is inherited from CIM_ManagedSystemElement.

Values include the following:

"OK"
"Error"
"Degraded"
"Unknown"
"Pred Fail"
"Starting"
"Stopping"
"Service"
"Stressed"
"NonRecover"
"No Contact"
"Lost Comm"
Tag
Data type: string
Access type: Read-only

Arbitrary string that uniquely identifies the physical element and serves as the element's key. This property can contain information, such as asset tag or serial number data. The key for CIM_PhysicalElement is placed very high in the object hierarchy to independently identify the hardware/entity, regardless of physical placement in (or on) cabinets, adapters, and so on. For example, a removable component that can be hot-swapped can be taken from its containing (scoping) package and be temporarily unused. The object still continues to exist and can even be inserted into a different scoping container. The key for a physical element is an arbitrary string that is defined independently of placement or location-oriented hierarchy. This property is inherited from CIM_PhysicalElement.

Version
Data type: string
Access type: Read-only

Version of the physical element. This property is inherited from CIM_PhysicalElement.

Remarks

The CIM_PhysicalConnector class is derived from CIM_PhysicalElement.

WMI does not implement this class. For WMI classes that are derived from CIM_PhysicalConnector, see Win32 Classes.

This documentation is derived from the CIM class descriptions published by the DMTF. Microsoft may have made changes to correct minor errors, conform to Microsoft SDK documentation standards, or provide more information.

Requirements

Minimum supported client

Windows Vista

Minimum supported server

Windows Server 2003

Namespace

\root\CIMV2

MOF

CIMWin32.mof

DLL

CIMWin32.dll

 

 

Mostrar:
© 2014 Microsoft