StorPortSetPowerSettingNotificationGuids routine

The StorPortSetPowerSettingNotificationGuids routine enables a miniport to receive power setting notifications. The miniport registers an array of GUIDs which identify the power settings to receive power change notifications for.

Syntax


ULONG StorPortSetPowerSettingNotificationGuids(
  _In_  PVOID HwDeviceExtension,
  _In_  ULONG GuidCount,
  _In_  LPGUID Guid
);

Parameters

HwDeviceExtension [in]

A pointer to the hardware device extension for the host bus adapter (HBA).

GuidCount [in]

The number of GUIDs in the Guid array.

Guid [in]

An array of power setting GUIDs to register for notification. A typical use for registering these GUIDs is for SATA miniports to receive notifications for AHCI Link Power Management setting changes. The AHCI Link Power Management settings defined by the Microsoft AHCI StorPort miniport driver are the following.

HIPM/DIPM Setting (0b2d69d7-a2a1-449c-9680-f91c70521c60)

Configures the link power management mode for disk and storage devices that are attached to the system through an AHCI interface.

IndexNameDescription
0ActiveLink power management is not used.
1HIPMHost-Initiated Power Management (HIPM) is used.
2HIPM and DIPMHIPM and Device-Initiated Power Management (DIPM) are used.

 

Adaptive Setting (dab60367-53fe-4fbc-825e-521d069d2456)

The period of AHCI link idle time before the link is put into a slumber state when HIPM or DIPM is enabled.

ValueDescription
0Minimum value in milliseconds (only use Partial state).
...Any intermediate value.
300000Maximum value in milliseconds (5 minutes).

 

Other miniports may define and register their own power setting GUIDs.

Return value

The StorPortSetPowerSettingNotificationGuids routine returns one of these status codes:

Return codeDescription
STOR_STATUS_INSUFFICIENT_RESOURCES

Insufficient resources are available to register for notifications.

STOR_STATUS_SUCCESS

The notification GUIDs were registered successfully.

 

Remarks

A miniport calls StorPortSetPowerSettingNotificationGuids in its HwStorFindAdapter routine to register the GUIDs it requests to receive notifications for.

When a power state change occurs for a registered notification, the miniport is notified in its HwStorAdapterControl routine. The control type of ScsiPowerSettingNotification is set in the ControlType parameter.

The AHCI Link Power management settings are part of the Disk Settings subgroup (0012ee47-9041-4b5d-9b77-535fba8b1442) in the power policy configuration. These are managed under the SUB_DISK configuration alias with powercfg.exe.

Requirements

Version

Available in starting with Windows 8.

Header

Storport.h (include Storport.h)

IRQL

Any

See also

HwStorFindAdapter
HwStorAdapterControl

 

 

Send comments about this topic to Microsoft