FltCreateNamedPipeFile function
Minifilter drivers call FltCreateNamedPipeFile to create a new pipe or open an existing pipe.
Syntax
NTSTATUS FltCreateNamedPipeFile( _In_ PFLT_FILTER Filter, _In_opt_ PFLT_INSTANCE Instance, _Out_ PHANDLE FileHandle, _Out_opt_ PFILE_OBJECT *FileObject, _In_ ACCESS_MASK DesiredAccess, _In_ POBJECT_ATTRIBUTES ObjectAttributes, _Out_ PIO_STATUS_BLOCK IoStatusBlock, _In_ ULONG ShareAccess, _In_ ULONG CreateDisposition, _In_ ULONG CreateOptions, _In_ ULONG NamedPipeType, _In_ ULONG ReadMode, _In_ ULONG CompletionMode, _In_ ULONG MaximumInstances, _In_ ULONG InBoundQuota, _In_ ULONG OutBoundQuota, _In_opt_ PLARGE_INTEGER DefaultTimeout, _In_opt_ PIO_DRIVER_CREATE_CONTEXT DriverContext );
Parameters
- Filter [in]
-
An opaque filter pointer for the caller.
- Instance [in, optional]
-
An opaque instance pointer for the minifilter driver instance that the create request is to be sent to. The instance must be attached to the volume for the named pipe file system. This parameter is optional and can be NULL. If this parameter is NULL, the request is sent to the device object at the top of the file system driver stack for the volume. If it is non-NULL, the request is sent only to minifilter driver instances that are attached below the specified instance.
- FileHandle [out]
-
A pointer to a caller-allocated variable that receives the file handle if the call to FltCreateNamedPipeFile is successful.
- FileObject [out, optional]
-
A pointer to a caller-allocated variable that receives the file object pointer if the call to FltCreateNamedPipeFile is successful. This parameter is optional and can be NULL.
- DesiredAccess [in]
-
A bitmask of flags that specify the type of access that the caller requires to the file or directory. The set of system-defined DesiredAccess flags determines the following specific access rights for file objects.
DesiredAccess Flags Meaning FILE_READ_DATA
Data can be read from the named pipe.
FILE_READ_ATTRIBUTES
FileAttributes flags can be read. For additional information, see the table of valid flag values in the FileAttributes parameter of FltCreateFileEx2.
READ_CONTROL
The access control list (ACL) and ownership information associated with the named pipe can be read.
FILE_WRITE_DATA
Data can be written to the named pipe.
FILE_WRITE_ATTRIBUTES
FileAttributes flags can be written.
FILE_APPEND_DATA
Data can be appended to the file.
WRITE_DAC
The discretionary access control list (DACL) associated with the named pipe can be written.
WRITE_OWNER
Ownership information associated with the named pipe can be written.
ACCESS_SYSTEM_SECURITY
The caller will have write access to the named pipe's SACL
SYNCHRONIZE
The caller can synchronize the completion of an I/O operation by waiting for the returned FileHandle to be set to the Signaled state. This flag must be set if the CreateOptions FILE_SYNCHRONOUS_IO_ALERT or FILE_SYNCHRONOUS_IO_NONALERT flag is set.
Alternatively, for any file object that does not represent a directory, you can specify one or more of the following generic ACCESS_MASK flags. (The STANDARD_RIGHTS_XXX flags are predefined system values that are used to enforce security on system objects.) You can also combine these generic flags with additional flags from the preceding table.
DesiredAccess to File Values Maps to DesiredAccess Flags GENERIC_READ
STANDARD_RIGHTS_READ, FILE_READ_DATA, and SYNCHRONIZE.
GENERIC_WRITE
STANDARD_RIGHTS_WRITE, FILE_WRITE_DATA, FILE_APPEND_DATA, and SYNCHRONIZE.
- ObjectAttributes [in]
-
A pointer to an opaque OBJECT_ATTRIBUTES structure that is already initialized with InitializeObjectAttributes. If the caller is running in the system process context, this parameter can be NULL. Otherwise, the caller must set the OBJ_KERNEL_HANDLE attribute in the call to InitializeObjectAttributes. Members of this structure for a file object are listed in the following table.
Member Value ULONG Length
The number of bytes of data that are contained in the structure pointed to by ObjectAttributes. This value must be at least sizeof(OBJECT_ATTRIBUTES).
PUNICODE_STRING ObjectName
A pointer to a UNICODE_STRING structure that contains the name of the pipe to be created or opened. This name must be a fully qualified file specification or the name of a device object unless it is the name of a file relative to the directory specified by RootDirectory. For example, "\Device\NamedPipe\mypipe" or "\??\pipe\mypipe" could both be valid file specifications. (Note: "\??" replaces "\DosDevices" as the name of the Win32 object namespace. "\DosDevices" still works, but "\??" is translated faster by the object manager.)
HANDLE RootDirectory
An optional handle to a directory, obtained by a preceding call to FltCreateFileEx2. If this value is NULL, the ObjectNamemember must be a fully qualified file specification that includes the full path to the target pipe. If this value is non-NULL, the ObjectName member specifies a pipe name that is relative to this directory.
PSECURITY_DESCRIPTOR SecurityDescriptor
An optional security descriptor (SECURITY_DESCRIPTOR) to be applied to a pipe. ACLs specified by such a security descriptor are only applied to the pipe when it is created. If the value is NULL when a pipe is created, the ACL placed on the pipe is dependant on the named pipe file system and may allow a client with any access to create an instance.
ULONG Attributes
A set of flags that controls the file object attributes. If the caller is running in the system process context, this parameter can be zero. Otherwise, the caller must set the OBJ_KERNEL_HANDLE flag. The caller can also optionally set the OBJ_CASE_INSENSITIVE flag, which indicates that name-lookup code should ignore the case of ObjectName rather than performing an exact-match search.
- IoStatusBlock [out]
-
A pointer to an IO_STATUS_BLOCK structure that receives the final completion status and information about the requested operation. On return from FltCreateNamedPipeFile, the Information member of the variable contains one of the following values:
-
FILE_CREATED
-
FILE_OPENED
-
- ShareAccess [in]
-
The type of share access to the file that the caller requires as one or a combination of the following flags. For the greatest chance of avoiding sharing violation errors, specify all of the following share access flags.
ShareAccess flags Meaning FILE_SHARE_READ
The file can be opened for read access by other threads' calls to FltCreateNamedPipeFile.
FILE_SHARE_WRITE
The file can be opened for write access by other threads' calls to FltCreateNamedPipeFile.
- CreateDisposition [in]
-
A value that determines the action to be taken, depending on whether the file already exists. The value can be any of those described in the following table.
CreateDisposition values Meaning FILE_CREATE
If the file already exists, fail the request and do not create or open the specified file. If it does not, create the file.
FILE_OPEN
If the file already exists, open it instead of creating a new file. If it does not, fail the request and do not create a new file.
FILE_OPEN_IF
If the file already exists, open it. If it does not, create the file.
- CreateOptions [in]
-
The options to be applied when creating or opening the pipe, as a compatible combination of the following flags.
CreateOptions flags Meaning FILE_WRITE_THROUGH
System services, pipe systems, and drivers that write data to the pipe must actually transfer the data into the pipe before any requested write operation is considered complete. This flag is automatically set if the CreateOptions flag FILE_NO_INTERMEDIATE_BUFFERING is set.
FILE_SYNCHRONOUS_IO_ALERT
All operations on the pipe are performed synchronously. Any wait on behalf of the caller is subject to premature termination from alerts. This flag also causes the I/O system to maintain the pipe position context. If this flag is set, the DesiredAccess SYNCHRONIZE flag also must be set so that the I/O Manager uses the file object as a synchronization object.
FILE_SYNCHRONOUS_IO_NONALERT
All operations on the pipe are performed synchronously. Waits in the system to synchronize I/O queuing and completion are not subject to alerts. This flag also causes the I/O system to maintain the file position context. If this flag is set, the DesiredAccess SYNCHRONIZE flag also must be set so that the I/O Manager uses the file object as a synchronization object.
- NamedPipeType [in]
-
The mode to read from the pipe.
- ReadMode [in]
-
The mode to read from the pipe.
- CompletionMode [in]
-
The completion mode for pipe reads and writes.
- MaximumInstances [in]
-
The maximum number of instances allowed for this named pipe.
- InBoundQuota [in]
-
The number of bytes to reserve for the input buffer.
- OutBoundQuota [in]
-
The number of bytes to reserve for the output buffer.
- DefaultTimeout [in, optional]
-
The default timeout in 100-nanosecond increments. This value is expressed as a negative integer. For example, 250 milliseconds is specified as –10 * 1000 * 250.
- DriverContext [in, optional]
-
An optional pointer to an IO_DRIVER_CREATE_CONTEXT structure already initialized by IoInitializeDriverCreateContext.
Return value
FltCreateNamedPipeFile returns STATUS_SUCCESS or an appropriate NTSTATUS value such as one of the following.
| Return code | Description |
|---|---|
|
The filter or instance specified in the Filter or Instance parameters is being torn down. This status code can be received if the open request crosses a volume mount point and the Instance parameter is non-NULL. This is an error code. |
|
The ObjectAttributes parameter did not contain a RootDirectory member, but the ObjectName member in the OBJECT_ATTRIBUTES structure was an empty string or did not contain an OBJECT_NAME_PATH_SEPARATOR character. This error code indicates incorrect syntax for the object path. |
Remarks
The FltCreateNamedPipeFile function allows minifilter drivers to create or open pipe instances. This is useful for creating virtual pipes or for creating pipe unions for multiplexing I/O.
The instance parameter is either NULL or is previously set by attaching to the named pipe volume. A volume pointer is obtained by passing "\Device\NamedPipe" as the volume name to FltGetVolumeFromName.
To specify an extra create parameter (ECP) as part of a create operation, initialize the ExtraCreateParameter member of the IO_DRIVER_CREATE_CONTEXT structure with the FltAllocateExtraCreateParameterList routine. If ECPs are used, they must be allocated, initialized, and freed using their associated support routines. Upon returning from the call of FltCreateNamedPipeFile, the ECP list is unchanged and may be passed to additional calls of FltCreateNamedPipeFile for other create operations. The ECP list structure is not automatically deallocated. The caller of FltCreateNamedPipeFile must deallocate this structure by calling the FltFreeExtraCreateParameterList routine.
If Instance is not NULL, the create request from FltCreateNamedPipeFile is sent only to the instances attached below the specified minifilter driver instance and to the named pipe file system. The specified instance and the instances attached above it do not receive the create request. If no instance is specified, the request goes to the top of the stack and is received by all instances and the named pipe file system.
Requirements
|
Version | Available in Windows 8. |
|---|---|
|
Header |
|
|
Library |
|
|
IRQL | PASSIVE_LEVEL |
See also
- FltFreeExtraCreateParameterList
- FltAllocateExtraCreateParameterList
- InitializeObjectAttributes
- IO_DRIVER_CREATE_CONTEXT
- IoInitializeDriverCreateContext
Send comments about this topic to Microsoft
Build date: 11/21/2012