HidP_SetUsages routine

The HidP_SetUsages routine sets specified HID control buttons ON (1) in a HID report.

Syntax


NTSTATUS __stdcall HidP_SetUsages(
  _In_     HIDP_REPORT_TYPE ReportType,
  _In_     USAGE UsagePage,
  _In_     USHORT LinkCollection,
  _Inout_  PUSAGE UsageList,
  _Inout_  PULONG UsageLength,
  _In_     PHIDP_PREPARSED_DATA PreparsedData,
  _In_     PCHAR Report,
  _In_     ULONG ReportLength
);

Parameters

ReportType [in]

Specifies a HIDP_REPORT_TYPE enumerator value that indicates the type of report located at Report.

UsagePage [in]

Specifies the usage page for the usages specified by UsageList.

LinkCollection [in]

Specifies the link collection that contains the usages. If LinkCollection is nonzero, the routine only sets the usages, if they exist, in this link collection. If LinkCollection is zero, the routine sets the first usage for each specified usage in the top-level collection associated with PreparsedData.

UsageList [in, out]

Pointer to the array of usages.

UsageLength [in, out]

Specifies, on input, the number of usages in UsageList. See the Remarks section for information about the output value.

PreparsedData [in]

Pointer to the preparsed data of the top-level collection associated with the report located at Report.

Report [in]

Pointer to a report.

ReportLength [in]

Specifies the size, in bytes, of the report located at Report, which must be equal to the report length for the specified report type that HidP_GetCaps returns in a collection's HIDP_CAPS structure.

Return value

HidP_SetUsages returns one of the following status values:

Return codeDescription
HIDP_STATUS_SUCCESS

The routine successfully set the usage value.

HIDP_STATUS_BUFFER_TOO_SMALL

A usage in a button array cannot be set because the array is already fully set.

HIDP_STATUS_INVALID_REPORT_LENGTH

The report length is not valid.

HIDP_STATUS_INVALID_REPORT_TYPE

The specified report type is not valid.

HIDP_STATUS_INCOMPATIBLE_REPORT_ID

A usage does not exist in the specified report, but it does exist in a different report of the specified type.

HIDP_STATUS_INVALID_PREPARSED_DATA

The preparsed data is not valid.

HIDP_STATUS_USAGE_NOT_FOUND

A usage does not exist in any report of the specified report type.

 

Remarks

If HidP_SetUsages cannot set a usage in UsageList, the routine sets UsageLength to the index of the usage that could not be set, and returns a status value that indicates the error.

For more information, see HID Collections.

Requirements

Version

Available in Windows 2000 and later versions of Windows.

Header

Hidpi.h (include Hidpi.h)

Library

Hidparse.lib

IRQL

<= DISPATCH_LEVEL

See also

_HIDP_PREPARSED_DATA
HidP_GetButtons
HidP_GetUsages
HidP_SetButtons
HidP_UnsetButtons
HidP_UnsetUsages

 

 

Send comments about this topic to Microsoft