Control Pattern Property Identifiers

This topic describes the named constants used to identify the properties associated with specific Microsoft UI Automation control patterns.

Constant/valueDescription
UIA_AnnotationAnnotationTypeIdPropertyId
30113

Identifies the AnnotationTypeId property of the Annotation control pattern. Supported starting with Windows 8.

This property indicates the type of an annotation. For a list of possible values, see Annotation Type Identifiers.

Variant type: VT_I4

Default value: AnnotationType_Unknown

UIA_AnnotationAnnotationTypeNamePropertyId
30114

Identifies the AnnotationTypeName property of the Annotation control pattern. Supported starting with Windows 8.

This property is a localized string that contains the name of an annotation type. The name can correspond to one of the annotation type identifiers (for example, “Comment” for AnnotationType_Comment), but it is not required to.

Variant type: VT_BSTR

Default value: empty string

UIA_AnnotationAuthorPropertyId
30115

Identifies the Author property of the Annotation control pattern. Supported starting with Windows 8.

This property is a string that contains the name of the person who authored the annotation.

Variant type: VT_BSTR

Default value: empty string

UIA_AnnotationDateTimePropertyId
30116

Identifies the DateTime property of the Annotation control pattern. Supported starting with Windows 8.

This property is a string that contains the date and time when the annotation was created.

Variant type: VT_BSTR

Default value: empty string

UIA_AnnotationTargetPropertyId
30117

Identifies the Target property of the Annotation control pattern. Supported starting with Windows 8.

This property is the IUIAutomationElement interface of the element that is being annotated.

Variant type: VT_UNKNOWN

Default value: NULL

UIA_DockDockPositionPropertyId
30069

Identifies the DockPosition property of the Dock control pattern.

This property indicates the dock position of the automation element within a docking container, and is expressed as a value from the DockPosition enumerated type.

Variant type: VT_I4

Default value: DockPosition_None

UIA_DragDropEffectPropertyId
30139

Identifies the DropEffect property of the Drag control pattern. Supported starting with Windows 8.

This property indicates what happens when an element is dropped as part of a drag-drop operation.

Variant type: VT_BSTR

Default value: empty string

UIA_DragDropEffectsPropertyId
30140

Identifies the DropEffects property of the Drag control pattern. Supported starting with Windows 8.

This property is a collection of strings that enumerate the possible effects that can happen when an element is dropped as part of a drag-drop operation.

Variant type: VT_BSTR | VT_ARRAY

Default value: empty array

UIA_DragIsGrabbedPropertyId
30138

Identifies the IsGrabbed property of the Drag control pattern. Supported starting with Windows 8.

This property indicates whether an element is being dragged.

Variant type: VT_BOOL

Default value: FALSE

UIA_DragGrabbedItemsPropertyId
30144

Identifies the GrabbedItems property of the Drag control pattern. Supported starting with Windows 8.

This property is a collection of elements that are being dragged as part of a drag operation.

Variant type: VT_BSTR | VT_ARRAY

Default value: empty array

UIA_DropTargetDropTargetEffectPropertyId
30142

Identifies the DropTargetEffect property of the DropTarget control pattern. Supported starting with Windows 8.

This property indicates the current drop effect for the element being dragged.

Variant type: VT_BSTR

Default value: empty string

UIA_DropTargetDropTargetEffectsPropertyId
30143

Identifies the DropTargetEffects property of the DropTarget control pattern. Supported starting with Windows 8.

This property indicates the possible drop effects that can happen when an element is dropped on a drop target.

Variant type: VT_BSTR | VT_ARRAY

Default value: empty array

UIA_ExpandCollapseExpandCollapseStatePropertyId
30070

Identifies the ExpandCollapseState property of the ExpandCollapse control pattern.

This property indicates the current state, expanded or collapsed, of the automation element, and is expressed as a value from the ExpandCollapseState enumerated type.

Variant type: VT_I4

Default value: ExpandCollapseState_LeafNode

UIA_GridColumnCountPropertyId
30063

Identifies the ColumnCount property of the Grid control pattern.

This property indicates the total number of columns in the grid.

Variant type: VT_I4

Default value: 0

UIA_GridItemColumnPropertyId
30065

Identifies the Column property of the GridItem control pattern.

This property indicates the ordinal number of the column that contains the cell or item.

Variant type: VT_I4

Default value: 0

UIA_GridItemColumnSpanPropertyId
30067

Identifies the ColumnSpan property of the GridItem control pattern.

This property indicates the number of columns spanned by the cell or item.

Variant type:VT_I4

Default value: 1

UIA_GridItemContainingGridPropertyId
30068

Identifies the ContainingGrid property of the GridItem control pattern.

This property is the IUIAutomationElement interface pointer of the automation element that contains the cell or item. The container element implements the Grid control pattern (IGridProvider).

Variant type: VT_UNKNOWN

Default value: NULL

UIA_GridItemRowPropertyId
30064

Identifies the Row property of the GridItem control pattern.

This property is the ordinal number of the row that contains the cell or item.

Variant type: VT_I4

Default value: 0

UIA_GridItemRowSpanPropertyId
30066

Identifies the RowSpan property of the GridItem control pattern.

This property indicates the number of rows spanned by the cell or item.

Variant type: VT_I4

Default value: 1

UIA_GridRowCountPropertyId
30062

Identifies the RowCount property of the Grid control pattern.

This property indicates the total number of rows in the grid.

Variant type: VT_I4

Default value: 0

UIA_LegacyIAccessibleChildIdPropertyId
30091

Identifies the ChildId property of the LegacyIAccessible control pattern.

This property is the Microsoft Active Accessibility (MSAA) child identifier of the automation element.

Variant type: VT_I4

Default value: 0

UIA_LegacyIAccessibleDefaultActionPropertyId
30100

Identifies the DefaultAction property of the LegacyIAccessible control pattern.

This property is the MSAA default action (accDefaultAction) for the automation element.

Variant type: VT_BSTR

Default value: empty string

UIA_LegacyIAccessibleDescriptionPropertyId
30094

Identifies the Description property of the LegacyIAccessible control pattern.

This property is the MSAA description (accDescription) for the automation element.

Variant type: VT_BSTR

Default value: empty string

UIA_LegacyIAccessibleHelpPropertyId
30097

Identifies the Help property of the LegacyIAccessible control pattern.

This property is the MSAA help string (accHelp) for the automation element.

Variant type: VT_BSTR

Default value: empty string

UIA_LegacyIAccessibleKeyboardShortcutPropertyId
30098

Identifies the KeyboardShortcut property of the LegacyIAccessible control pattern.

This property is the MSAA keyboard shortcut string (accKeyboardShortcut) for the automation element.

Variant type: VT_BSTR

Default value: empty string

UIA_LegacyIAccessibleNamePropertyId
30092

Identifies the Name property of the LegacyIAccessible control pattern.

This property is the MSAA name string (accName) for the automation element.

Variant type: VT_BSTR

Default value: empty string

UIA_LegacyIAccessibleRolePropertyId
30095

Identifies the Role property of the LegacyIAccessible control pattern.

This property is the MSAA role identifier (accRole) for the automation element.

Variant type: VT_I4

Default value: 0

UIA_LegacyIAccessibleSelectionPropertyId
30099

Identifies the Selection property of the LegacyIAccessible control pattern.

This property is the MSAA list of selected items (accSelection) in the control represented by the automation element.

Variant type: VT_UNKNOWN | VT_ARRAY

Default value: empty array

UIA_LegacyIAccessibleStatePropertyId
30096

Identifies the State property of the LegacyIAccessible control pattern.

This property is the MSAA state (accState) of the automation element.

Variant type: VT_I4

Default value: 0

UIA_LegacyIAccessibleValuePropertyId
30093

Identifies the Value property of the LegacyIAccessible control pattern.

This property is the MSAA value (accValue) of the automation element.

Variant type: VT_BSTR

Default value: empty string

UIA_MultipleViewCurrentViewPropertyId
30071

Identifies the CurrentView property of the MultipleView control pattern.

This property indicates the current view state of the automation element.

Variant type: VT_I4

Default value: 0

UIA_MultipleViewSupportedViewsPropertyId
30072

Identifies the SupportedViews property of the MultipleView control pattern.

This property is a list of identifiers for the view states supported by the automation element.

Variant type: VT_I4 | VT_ARRAY

Default value: empty array

UIA_RangeValueIsReadOnlyPropertyId
30048

Identifies the IsReadOnly property of the RangeValue control pattern.

This property indicates whether the value of the automation element is read-only.

Variant type: VT_BOOL

Default value: TRUE

UIA_RangeValueLargeChangePropertyId
30051

Identifies the LargeChange property of the RangeValue control pattern.

This property is the large-change value, unique to the automation element, that is added to or subtracted from the Value property.

Variant type: VT_R8

Default value: 0

UIA_RangeValueMaximumPropertyId
30050

Identifies the Maximum property of the RangeValue control pattern.

This property is the maximum range value supported by the automation element.

Variant type: VT_R8

Default value: 0

UIA_RangeValueMinimumPropertyId
30049

Identifies the Minimum property of the RangeValue control pattern.

This property is the minimum range value supported by the automation element.

Variant type: VT_R8

Default value: 0

UIA_RangeValueSmallChangePropertyId
30052

Identifies the SmallChange property of the RangeValue control pattern.

This property is the small-change value, unique to the automation element, that is added to or subtracted from the Value property.

Variant type: VT_R8

Default value: 0

UIA_RangeValueValuePropertyId
30047

Identifies the Value property of the RangeValue control pattern.

This property is the current value of the automation element.

Variant type: VT_R8

Default value: 0

UIA_ScrollHorizontallyScrollablePropertyId
30057

Identifies the HorizontallyScrollable property of the Scroll control pattern.

This property indicates whether the automation element can scroll horizontally.

Variant type: VT_BOOL

Default value: FALSE

UIA_ScrollHorizontalScrollPercentPropertyId
30053

Identifies the HorizontalScrollPercent property of the Scroll control pattern.

This property is the current horizontal scroll position expressed as a percentage of the total content area within the automation element.

Variant type: VT_R8

Default value: 0

UIA_ScrollHorizontalViewSizePropertyId
30054

Identifies the HorizontalViewSize property of the Scroll control pattern.

This property is the horizontal size of the viewable region expressed as a percentage of the total content area within the element.

Variant type: VT_R8

Default value: 100

UIA_ScrollVerticallyScrollablePropertyId
30058

Identifies the VerticallyScrollable property of the Scroll control pattern.

This property indicates whether the automation element can scroll vertically.

Variant type: VT_BOOL

Default value: FALSE

UIA_ScrollVerticalScrollPercentPropertyId
30055

Identifies the VerticalScrollPercent property of the Scroll control pattern.

This property is the current vertical scroll position expressed as a percentage of the total content area within the automation element.

Variant type: VT_R8

Default value: 0

UIA_ScrollVerticalViewSizePropertyId
30056

Identifies the VerticalViewSize property of the Scroll control pattern.

This property is the vertical size of the viewable region expressed as a percentage of the total content area within the element.

Variant type: VT_R8

Default value: 100

UIA_SelectionCanSelectMultiplePropertyId
30060

Identifies the CanSelectMultiple property of the Selection control pattern.

This property indicates whether the automation element allows more than one child element to be selected concurrently.

Variant type: VT_BOOL

Default value: FALSE

UIA_SelectionIsSelectionRequiredPropertyId
30061

Identifies the IsSelectionRequired property of the Selection control pattern.

This property indicates whether the automation element requires at least one child item to be selected.

Variant type: VT_BOOL

Default value: FALSE

UIA_SelectionSelectionPropertyId
30059

Identifies the Selection property of the Selection control pattern.

This property is a collection of the selected child elements, and is expressed as an IUIAutomationElementArray pointer.

Variant type: VT_UNKNOWN | VT_ARRAY

Default value: empty array

UIA_SelectionItemIsSelectedPropertyId
30079

Identifies the IsSelected property of the SelectionItem control pattern.

This property indicates whether the automation element is selected.

Variant type: VT_BOOL

Default value: FALSE

UIA_SelectionItemSelectionContainerPropertyId
30080

Identifies the SelectionContainer property of the SelectionItem control pattern.

This property is the IUIAutomationElement interface pointer for the automation element that contains the current element.

Variant type: VT_UNKNOWN

Default value: NULL

UIA_SpreadsheetItemFormulaPropertyId
30129

Identifies the Formula property of the SpreadsheetItem control pattern.

This property is a string that contains the formula for the spreadsheet cell. Supported starting with Windows 8.

Variant type: VT_BSTR

Default value: NULL

UIA_SpreadsheetItemAnnotationObjectsPropertyId
30130

Identifies the AnnotationObjects property of the SpreadsheetItem control pattern.

This property is a collection of UI Automation elements representing the annotations associated with the spreadsheet cell. The collection is expressed as an IUIAutomationElementArray interface. Supported starting with Windows 8.

Variant type: VT_UNKNOWN | VT_ARRAY

Default value: NULL

UIA_SpreadsheetItemAnnotationTypesPropertyId
30131

Identifies the AnnotationTypes property of the SpreadsheetItem control pattern. Supported starting with Windows 8.

This property is array of annotation type identifiers, one for each type of annotation associated with the spreadsheet cell. For a list of possible values, see Annotation Type Identifiers.

Variant type: VT_I4 | VT_ARRAY

Default value: empty array

UIA_StylesExtendedPropertiesPropertyId
30126

Identifies the ExtendedProperties property of the Styles control pattern.

This property contains a localized, formatted string that contains additional properties that are not included in the Styles control pattern, but that provide information about the document content that might be useful to the user. The format of the string is as follows: "prop1=value;prop2=value2". Supported starting with Windows 8.

Variant type: VT_BSTR

Default value: empty string

UIA_StylesFillColorPropertyId
30122

Identifies the FillColor property of the Styles control pattern.

This property specifies the color used to fill an element. This property is expressed as a COLORREF, a 32-bit value used to specify an RGB or RGBA color. Supported starting with Windows 8.

Variant type: VT_I4

Default value: 0

UIA_StylesFillPatternColorPropertyId
30125

Identifies the FillPatternColor property of the Styles control pattern.

This property specifies the color of the pattern used to fill an element. This property is expressed as a COLORREF, a 32-bit value used to specify an RGB or RGBA color. Supported starting with Windows 8.

Variant type: VT_I4

Default value: 0

UIA_StylesFillPatternStylePropertyId
30123

Identifies the FillPatternStyle property of the Styles control pattern.

This property is a localized string that contains the style of the pattern used to fill an element, such as "Vertical Stripe". Supported starting with Windows 8.

Variant type: VT_BSTR

Default value: empty string

UIA_StylesShapePropertyId
30124

Identifies the Shape property of the Styles control pattern.

This property is a localized string that indicates the shape of the element. Supported starting with Windows 8.

Variant type: VT_BSTR

Default value: empty string

UIA_StylesStyleIdPropertyId
30120

Identifies the StyleId property of the Styles control pattern.

This property identifies the visual style of the element. For a list of possible values, see Style Identifiers. Supported starting with Windows 8.

Variant type: VT_I4

Default value: 0

UIA_StylesStyleNamePropertyId
30121

Identifies the StyleName property of the Styles control pattern.

This property is the name of the visual style of the element. Supported starting with Windows 8.

Variant type: VT_BSTR

Default value: empty string

UIA_TableColumnHeadersPropertyId
30082

Identifies the ColumnHeaders property of the Table control pattern.

This property is a collection of automation elements for all column headers in the table, and is expressed as an IUIAutomationElementArray interface pointer.

Variant type: VT_UNKNOWN | VT_ARRAY

Default value: empty array

UIA_TableItemColumnHeaderItemsPropertyId
30085

Identifies the ColumnHeaderItems property of the TableItem control pattern.

This property is a collection of automation elements for all column headers in the table item or cell, and is expressed as an IUIAutomationElementArray interface pointer.

Variant type: VT_UNKNOWN | VT_ARRAY

Default value: empty array

UIA_TableRowHeadersPropertyId
30081

Identifies the RowHeaders property of the Table control pattern.

This property is a collection of automation elements for all row headers in the table, and is expressed as an IUIAutomationElementArray interface pointer.

Variant type: VT_UNKNOWN | VT_ARRAY

Default value: empty array

UIA_TableRowOrColumnMajorPropertyId
30083

Identifies the RowOrColumnMajor property of the Table control pattern.

This property indicates the primary direction of traversal for the table, and is expressed as a value from the RowOrColumnMajor enumerated type.

Variant type: VT_I4 | VT_ARRAY

Default value: RowOrColumnMajor_Indeterminate

UIA_TableItemRowHeaderItemsPropertyId
30084

Identifies the RowHeaderItems property of the TableItem control pattern.

This property is a collection of automation elements for all row headers in the table item or cell, and is expressed as an IUIAutomationElementArray interface pointer.

Variant type: VT_UNKNOWN | VT_ARRAY

Default value: empty array

UIA_ToggleToggleStatePropertyId
30086

Identifies the ToggleState property of the Toggle control pattern.

This property indicates the toggle state of the automation element, and is expressed as a value from the ToggleState enumerated type.

Variant type: VT_I4

Default value: ToggleState_Indeterminate

UIA_TransformCanMovePropertyId
30087

Identifies the CanMove property of the Transform control pattern.

This property indicates whether the automation element can be moved.

Variant type: VT_BOOL

Default value: FALSE

UIA_TransformCanResizePropertyId
30088

Identifies the CanResize property of the Transform control pattern.

This property indicates whether the automation element can be resized.

Variant type: VT_BOOL

Default value: FALSE

UIA_TransformCanRotatePropertyId
30089

Identifies the CanRotate property of the Transform control pattern.

This property indicates whether the automation element can be rotated.

Variant type: VT_BOOL

Default value: FALSE

UIA_Transform2CanZoomPropertyId
30133

Identifies the CanZoom property of the Transform control pattern.

This property indicates whether the control supports zooming of its viewport. Supported starting with Windows 8.

Variant type: VT_BOOL

Default value: FALSE

UIA_Transform2ZoomLevelPropertyId
30145

Identifies the ZoomLevel property of the Transform control pattern. Supported starting with Windows 8.

This property indicates the current zooming level of the control's viewport.

Variant type: VT_R8

Default value: 0

UIA_Transform2ZoomMaximumPropertyId
30147

Identifies the ZoomMaximum property of the Transform control pattern. Supported starting with Windows 8.

This property indicates the maximum zooming level supported by the control's viewport.

Variant type: VT_R8

Default value: 0

UIA_Transform2ZoomMinimumPropertyId
30146

Identifies the ZoomMinimum property of the Transform control pattern. Supported starting with Windows 8.

This property indicates the minimum zooming level supported by the control's viewport.

Variant type: VT_R8

Default value: 0

UIA_ValueIsReadOnlyPropertyId
30046

Identifies the IsReadOnly property of the Value control pattern.

This property indicates whether the value of the automation element is read-only.

Variant type: VT_BOOL

Default value: TRUE

UIA_ValueValuePropertyId
30045

Identifies the Value property of the Value control pattern.

This property indicates the value of the automation element.

Variant type: VT_BSTR

Default value: empty string

UIA_WindowCanMaximizePropertyId
30073

Identifies the CanMaximize property of the Window control pattern.

This property indicates whether the window can be maximized.

Variant type: VT_BOOL

Default value: FALSE

UIA_WindowCanMinimizePropertyId
30074

Identifies the CanMinimize property of the Window control pattern.

This property indicates whether the window can be minimized.

Variant type: VT_BOOL

Default value: FALSE

UIA_WindowIsModalPropertyId
30077

Identifies the IsModal property of the Window control pattern.

This property indicates whether the window is modal.

Variant type: VT_BOOL

Default value: FALSE

UIA_WindowIsTopmostPropertyId
30078

Identifies the IsTopmost property of the Window control pattern.

This property indicates whether the window is the topmost element in the z-order.

Variant type: VT_BOOL

Default value: FALSE

UIA_WindowWindowInteractionStatePropertyId
30076

Identifies the WindowInteractionState property of the Window control pattern.

This property indicates the state of the window for the purposes of user interaction, and is expressed as a value from the WindowInteractionState enumerated type.

Variant type: VT_I4

Default value: WindowInteractionState_Running

UIA_WindowWindowVisualStatePropertyId
30075

Identifies the WindowVisualState property of the Window control pattern.

This property indicates the visual state of the window, and is expressed as a value from the WindowVisualState enumerated type.

Variant type: VT_I4

Default value: WindowVisualState_Normal

Requirements

Minimum supported client

Windows XP [desktop apps | Windows Store apps]

Minimum supported server

Windows Server 2003 [desktop apps | Windows Store apps]

Header

UIAutomationClient.h

See also

Conceptual
UI Automation Properties Overview
Retrieving Properties from UI Automation Elements
UI Automation Control Patterns Overview

 

 

Community Additions