Information
The topic you requested is included in another documentation set. For convenience, it's displayed below. Choose Switch to see the topic in its original location.

MSFT_WmiProvider_CreateClassEnumAsyncEvent_Post class

The MSFT_WmiProvider_CreateClassEnumAsyncEvent_Post event class represents an event generated immediately following completion of the provider's implementation of IWbemServices::CreateClassEnumAsync.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

class MSFT_WmiProvider_CreateClassEnumAsyncEvent_Post : MSFT_WmiProvider_OperationEvent_Post
{
  uint32 Flags;
  string HostingGroup;
  uint32 HostingSpecification;
  string Locale;
  string Namespace;
  object ObjectParameter;
  string Provider;
  uint32 ResultCode;
  uint8  SECURITY_DESCRIPTOR[];
  string StringParameter;
  string SuperclassName;
  uint64 TIME_CREATED;
  string TransactionIdentifier;
  string User;
};

Members

The MSFT_WmiProvider_CreateClassEnumAsyncEvent_Post class has these types of members:

Properties

The MSFT_WmiProvider_CreateClassEnumAsyncEvent_Post class has these properties.

Flags
Data type: uint32
Access type: Read-only

One or more of the following values are valid.

FlagMeaning
WBEM_FLAG_USE_AMENDED_QUALIFIERS

If this flag is set, WMI retrieves the amended qualifiers stored in the localized namespace of the current connection's locale. If not set, only the qualifiers stored in the immediate namespace are retrieved.

WBEM_FLAG_BIDIRECTIONAL

This flag causes WMI to retain pointers to objects of the enumeration until the client releases the enumerator.

WBEM_FLAG_DEEP

This flag forces the enumeration to include this and all subclasses in the hierarchy.

WBEM_FLAG_SHALLOW

This flag forces the enumeration to include only instances of this class, excluding all subclasses in the hierarchy.

WBEM_FLAG_SEND_STATUS

This flag registers with WMI a request to receive intermediate status reports through the client's implementation of IWbemObjectSink::SetStatus.

 

HostingGroup
Data type: string
Access type: Read-only

Second component of the __Win32Provider HostingModel property when the hosting model is one of LocalSystemHost, LocalSystemHostOrSelfHost, NetworkServiceHost, or LocalServiceHost. The hosting group defines a particular instantiation of a WMI provider host. Providers that share the same hosting model and hosting group share the same surrogate process.

HostingSpecification
Data type: uint32
Access type: Read-only

The first component of the __Win32ProviderHostingModel property. For the possible values of this property, see the HostingSpecification property in the MSFT_Providers class.

Locale
Data type: string
Access type: Read-only

Particular instantiation of a provider instance when the provider is configured for per local initialization.

Namespace
Data type: string
Access type: Read-only

Namespace associated with a particular provider instance.

ObjectParameter
Data type: object
Access type: Read-only

Extended status passed through provider's IWbemObjectSink::SetStatus call, possible NULL.

Provider
Data type: string
Access type: Read-only

Name associated with a particular provider instance. The name is identical to the __Win32Provider property.

ResultCode
Data type: uint32
Access type: Read-only

HRESULT status code of the operation.

SECURITY_DESCRIPTOR
Data type: uint8 array
Access type: Read-only

Descriptor used by the event provider to determine which users can receive the event. This property is inherited from __Event.

StringParameter
Data type: string
Access type: Read-only

This property is currently always NULL.

SuperclassName
Data type: string
Access type: Read-only

Specifies a parent class name, if not blank or NULL. Only classes that are subclasses of this class are returned. If NULL or blank, and Flags contains WBEM_FLAG_SHALLOW, only top-level classes, that is, those which have no parent class are returned. If it is NULL or blank and Flags is WBEM_FLAG_DEEP, all classes within the namespace are returned.

TIME_CREATED
Data type: uint64
Access type: Read-only

Unique value that indicates the time at which the event was generated. This property is inherited from __Event.

For more information about using uint64 values in scripts, see Scripting in WMI.

TransactionIdentifier
Data type: string
Access type: Read-only

Internal use only. The current value is "{00000000-0000-0000-0000-000000000000}".

User
Data type: string
Access type: Read-only

Particular provider instance, configured for per user initialization.

Requirements

Minimum supported client

Windows Vista

Minimum supported server

Windows Server 2003

Namespace

\root\CIMV2

MOF

System.mof

DLL

WmiPrvSD.dll

See also

Provider Event Troubleshooting Classes
MSFT_Providers
WMI Troubleshooting
WMI Troubleshooting
Receiving a WMI Event

 

 

Show:
© 2014 Microsoft