SkipNameResolutionForWebPublishingRules Property of IFPCWebProxy[C++] | FPCWebProxy.SkipNameResolutionForWebPublishingRules [Visual Basic]

Internet Security and Acceleration Server 2004/2006 SDK

The SkipNameResolutionForWebPublishingRules property gets or sets a Boolean value that indicates whether the ISA Server Web proxy will skip name resolution while checking Web publishing rules.


HRESULT get_SkipNameResolutionForWebPublishingRules(
  VARIANT_BOOL* pfSkipNameResolutionForWebPublishingRules );

HRESULT put_SkipNameResolutionForWebPublishingRules(
  VARIANT_BOOL fSkipNameResolutionForWebPublishingRules );

Parameters

pfSkipNameResolutionForWebPublishingRules
Pointer to a Boolean variable that is set on return to VARIANT_TRUE if the Web proxy will skip name resolution while checking Web publishing rules, or to VARIANT_FALSE if the Web proxy will not skip name resolution while checking Web publishing rules.
fSkipNameResolutionForWebPublishingRules
Boolean value that specifies whether the Web proxy will skip name resolution while checking Web publishing rules.

Return Values

These property methods return S_OK if the call is successful; otherwise, they return an error code.

Remarks

This property is read/write. Its default value is VARIANT_TRUE.

After the value of this property has been modified, the change must be written to persistent storage by calling the Save method, and the Microsoft Firewall service must be restarted for the change to take effect. For more information about restarting the Firewall service to apply changes, see Restarting Services After Configuration Changes.

The SkipNameResolutionForWebPublishingRules property gets or sets a Boolean value that indicates whether the ISA Server Web proxy will skip name resolution while checking Web publishing rules.


Property SkipNameResolutionForWebPublishingRules As Boolean

Property Value

Boolean value that indicates whether the Web proxy will skip name resolution while checking Web publishing rules.

Remarks

This property is read/write. Its default value is True.

After the value of this property has been modified, the change must be written to persistent storage by calling the Save method, and the Microsoft Firewall service must be restarted for the change to take effect. For more information about restarting the Firewall service to apply changes, see Restarting Services After Configuration Changes.

Requirements

Client Requires Windows XP.
Server Requires Windows Server 2003 or Windows 2000.
Version Requires Internet Security and Acceleration (ISA) Server 2006 or ISA Server 2004.
IDL

Declared in Msfpccom.idl.

DLL Requires Msfpccom.dll.