Each service has a control handler, the
Handler function, that is invoked by the control dispatcher when the service process receives a control request from a service control program. Therefore, this function executes in the context of the control dispatcher. For an example, see
Writing a Control Handler Function.
A service calls the
RegisterServiceCtrlHandler or RegisterServiceCtrlHandlerEx function to register its service control handler function.
Whenever
the service control handler is invoked, the service must call the
SetServiceStatus function to report its status to the SCM. This must be done regardless of whether the status changed.
A service control program can send control requests using the
ControlService function. All services must accept and process the SERVICE_CONTROL_INTERROGATE control code. You can enable or disable acceptance of the other control codes by calling
SetServiceStatus. To receive the SERVICE_CONTROL_DEVICEEVENT control code, you must call the
RegisterDeviceNotification function. Services can also handle additional user-defined control codes.
If a service accepts the SERVICE_CONTROL_STOP control code, it must stop upon receipt, going to either the SERVICE_STOP_PENDING or SERVICE_STOPPED state. After the SCM sends this control code, it will not send other control codes.
Windows XP/2000: If the service returns NO_ERROR and continues to run, it continues to receive control codes. This behavior changed starting with Windows Server 2003 and Windows XP with Service Pack 2 (SP2).
The control handler must return within 30 seconds, or the SCM returns an error. If a service must do lengthy processing when the service is executing the control handler, it should create a secondary thread to perform the lengthy processing, and then return from the control handler. This prevents the service from tying up the control dispatcher. For example, when handling the stop request for a service that takes a long time, create another thread to handle the stop process. The control handler should simply call
SetServiceStatus with the SERVICE_STOP_PENDING message and return.
When the user shuts down the system, all control handlers that have called SetServiceStatus with the SERVICE_ACCEPT_PRESHUTDOWN control code receive the SERVICE_CONTROL_PRESHUTDOWN control code. The service control manager waits until the service stops or the specified preshutdown time-out value expires (this value can be set with the ChangeServiceConfig2 function). This control code should be used only in special circumstances, because a service that handles this notification blocks system shutdown until the service stops or the preshutdown time-out interval expires.
After the preshutdown notifications have been completed, all control handlers that have called
SetServiceStatus with the SERVICE_ACCEPT_SHUTDOWN control code receive the SERVICE_CONTROL_SHUTDOWN control code. They are notified in the order that they appear in the database of installed services. By default, a service has approximately 20 seconds to perform cleanup tasks before the system shuts down. After this time expires, system shutdown proceeds regardless of whether service shutdown is complete. Note that if the system is left in the shutdown state (not restarted or powered down), the service continues to run.
If the service requires more time to cleanup, it sends STOP_PENDING status messages, along with a wait hint, so the service controller knows how long to wait before reporting to the system that service shutdown is complete. However, to prevent a service from stopping shutdown, there is a limit to how long the service controller waits. If the service is being shut down through the Services snap-in, the limit is 125 seconds. If the operating system is rebooting, the time limit is specified in the WaitToKillServiceTimeout value of the following registry key:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
Important A service should not attempt to increase the time limit by modifying this value.
Customers require fast shutdown of the operating system. For example, if a computer running on UPS power cannot complete shutdown before the UPS runs out of power, data can be lost. Therefore, services should complete their cleanup tasks as quickly as possible. It is a good practice to minimize unsaved data by saving data on a regular basis, keeping track of the data that is saved to disk, and only saving your unsaved data on shutdown. Because the computer is being shut down, do not spend time releasing allocated memory or other system resources. If you need to notify a server that you are exiting, minimize the time spent waiting for a reply, because network problems could delay the shutdown of your service.
Note that during service shutdown, the SCM does not take dependencies into consideration. The SCM enumerates the list of running services and sends the SERVICE_CONTROL_SHUTDOWN command. Therefore, a service may fail because another service it depends on has already stopped. To set the shutdown order of dependent services, use the SetProcessShutdownParameters function. The SCM uses this function to give its handler 0x1E0 priority. The SCM sends SERVICE_CONTROL_SHUTDOWN notifications when its control handler is called and waits for the services to exit before returning from its control handler.
See Also
- Writing a Control Handler Function
Send comments about this topic to Microsoft
Build date: 11/19/2009