ATA_PASS_THROUGH_DIRECT structure
The ATA_PASS_THROUGH_DIRECT structure is used in conjunction with an IOCTL_ATA_PASS_THROUGH_DIRECT request to instruct the port driver to send an embedded ATA command to the target device.
Syntax
typedef struct _ATA_PASS_THROUGH_DIRECT { USHORT Length; USHORT AtaFlags; UCHAR PathId; UCHAR TargetId; UCHAR Lun; UCHAR ReservedAsUchar; ULONG DataTransferLength; ULONG TimeOutValue; ULONG ReservedAsUlong; PVOID DataBuffer; UCHAR PreviousTaskFile[8]; UCHAR CurrentTaskFile[8]; } ATA_PASS_THROUGH_DIRECT, *PATA_PASS_THROUGH_DIRECT;
Members
- Length
-
Specifies the length in bytes of the ATA_PASS_THROUGH_DIRECT structure.
- AtaFlags
-
Indicates the direction of data transfer and specifies the kind of operation to be performed. The value of this member must be some combination of the flags in the following table.
ATA flags Meaning ATA_FLAGS_DRDY_REQUIRED
Wait for DRDY status from the device before sending the command to the device.
ATA_FLAGS_DATA_IN
Read data from the device.
ATA_FLAGS_DATA_OUT
Write data to the device.
ATA_FLAGS_48BIT_COMMAND
The ATA command to be sent uses the 48-bit logical block address (LBA) feature set. When this flag is set, the contents of the PreviousTaskFile member in the ATA_PASS_THROUGH_DIRECT structure should be valid.
ATA_FLAGS_USE_DMA
Set the transfer mode to DMA.
ATA_FLAGS_NO_MULTIPLE
Read single sector only.
- PathId
-
Contains an integer that indicates the IDE port or bus for the request. This value is set by the port driver.
- TargetId
-
Contains an integer that indicates the target device on the bus. This value is set by the port driver.
- Lun
-
Indicates the logical unit number of the device. This value is set by the port driver.
- ReservedAsUchar
-
Reserved for future use.
- DataTransferLength
-
Indicates the size, in bytes, of the data buffer. If an underrun occurs, the miniport driver must update this member to the number of bytes actually transferred.
- TimeOutValue
-
Indicates the number of seconds that are allowed for the request to execute before the OS-specific port driver determines that the request has timed out.
- ReservedAsUlong
-
Reserved for future use.
- DataBuffer
-
Pointer to the data buffer.
- PreviousTaskFile
-
Specifies the contents of the input task file register prior to the current pass-through command. This member is not used when the ATA_FLAGS_48BIT_COMMAND flag is not set.
- CurrentTaskFile
-
Specifies the content of the task file register on both input and output. On input, the array values in CurrentTaskFile map to the input registers in the following manner.
Byte Input Register 0
Features Register
1
Sector Count Register
2
Sector Number Register
3
Cylinder Low Register
4
Cylinder High Register
5
Device/Head Register
6
Command Register
7
Reserved
When IOCTL_ATA_PASS_THROUGH_DIRECT completes, the port driver updates CurrentTaskFile with the values that are present in the device's output registers at the completion of the embedded command. The array values in CurrentTaskFile correspond to the following task file output registers.
Byte Output Register 0
Error Register
1
Sector Count Register
2
Sector Number Register
3
Cylinder Low Register
4
Cylinder High Register
5
Device/Head Register
6
Status Register
7
Reserved
Remarks
The ATA_PASS_THROUGH_DIRECT structure is used with IOCTL_ATA_PASS_THROUGH_DIRECT. With this request, the system locks down the buffer in user memory and the device accesses this memory directly. For a double-buffered equivalent of this device control request, see IOCTL_ATA_PASS_THROUGH and ATA_PASS_THROUGH_EX.
Requirements
|
Header |
|
|---|
See also
Send comments about this topic to Microsoft
Build date: 5/17/2013