2.2.1.2.4 PidLidEmail1OriginalDisplayName, PidLidEmail2OriginalDisplayName, PidLidEmail3OriginalDisplayName Properties

Type: PtypString ([MS-OXCDATA] section 2.11.1)

The PidLidEmail1OriginalDisplayName ([MS-OXPROPS] section 2.103), PidLidEmail2OriginalDisplayName ([MS-OXPROPS] section 2.108), and PidLidEmail3OriginalDisplayName ([MS-OXPROPS] section 2.113) properties specify the Simple Mail Transfer Protocol (SMTP) email address corresponding to the email address specified in section 2.2.1.2.3 for the Contact object. If the value of the PidLidEmail1AddressType (section 2.2.1.2.2), PidLidEmail2AddressType (section 2.2.1.2.2), or PidLidEmail3AddressType (section 2.2.1.2.2) property is "SMTP", then the value of the respective PidLidEmail1OriginalDisplayName, PidLidEmail2OriginalDisplayName, or PidLidEmail3OriginalDisplayName property SHOULD equal the value of the respective PidLidEmail1EmailAddress (section 2.2.1.2.3), PidLidEmail2EmailAddress (section 2.2.1.2.3), or PidLidEmail3EmailAddress (section 2.2.1.2.3) property; otherwise, the values do not have to be equal. The purpose of the PidLidEmail1OriginalDisplayName, PidLidEmail2OriginalDisplayName, and PidLidEmail3OriginalDisplayName properties is to display an alternative user-friendly address that is equivalent to the one in the PidLidEmail1EmailAddress, PidLidEmail2EmailAddress, or PidLidEmail3EmailAddress property.