Export (0) Print
Expand All

ENABLE_TRACE_PARAMETERS_V1 structure

The ENABLE_TRACE_PARAMETERS_V1 structure defines the information used to enable a provider.

Syntax


typedef struct _ENABLE_TRACE_PARAMETERS_V1 {
  ULONG                    Version;
  ULONG                    EnableProperty;
  ULONG                    ControlFlags;
  GUID                     SourceId;
  PEVENT_FILTER_DESCRIPTOR EnableFilterDesc;
} ENABLE_TRACE_PARAMETERS_V1, *PENABLE_TRACE_PARAMETERS_V1;

Members

Version

Set to ENABLE_TRACE_PARAMETERS_VERSION.

EnableProperty

Optional information that ETW can include when writing the event. The data is written to the extended data item section of the event. To include the optional information, specify one or more of the following flags; otherwise, set to zero.

ValueMeaning
EVENT_ENABLE_PROPERTY_SID

Include in the extended data the security identifier (SID) of the user.

EVENT_ENABLE_PROPERTY_TS_ID

Include in the extended data the terminal session identifier.

EVENT_ENABLE_PROPERTY_STACK_TRACE

Include in the extended data a call stack trace for events written using EventWrite.

If you set EVENT_ENABLE_PROPERTY_STACK_TRACE, ETW will drop the event if the total event size exceeds 64K. If the provider is logging events close in size to 64K maximum, it is possible that enabling stack capture will cause the event to be lost.

If the stack is longer than the maximum number of frames (192), the frames will be cut from the bottom of the stack.

For consumers, the events will include the EVENT_EXTENDED_ITEM_STACK_TRACE32 or EVENT_EXTENDED_ITEM_STACK_TRACE64 extended item. Note that on 64-bit computers, 32-bit processes will receive 64-bit stack traces.

 

ControlFlags

Reserved. Set to 0.

SourceId

A GUID that uniquely identifies the session that is enabling or disabling the provider. If the provider does not implement EnableCallback, the GUID is not used.

EnableFilterDesc

An EVENT_FILTER_DESCRIPTOR structure that points to the filter data. The provider uses filter data to prevent events that match the filter criteria from being written to the session. The provider determines the layout of the data and how it applies the filter to the event's data. A session can pass only one filter to the provider.

A session can call the TdhEnumerateProviderFilters function to determine the schematized filters that it can pass to the provider.

Remarks

The ENABLE_TRACE_PARAMETERS_V1 structure is used with the EnableTrace and EnableTraceEx functions. The ENABLE_TRACE_PARAMETERS structure is a version 2 structure and replaces the ENABLE_TRACE_PARAMETERS_V1 structure for use with the EnableTraceEx2 function.

Typically, on 64-bit computers, you cannot capture the kernel stack in certain contexts when page faults are not allowed. To enable walking the kernel stack on x64, set the DisablePagingExecutive Memory Management registry value to 1. The DisablePagingExecutive registry value is located under the following registry key:

HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Session Manager\Memory Management

You should consider the cost of setting this registry value before doing so.

Requirements

Minimum supported client

Windows 7 [desktop apps only]

Minimum supported server

Windows Server 2008 R2 [desktop apps only]

Header

Evntrace.h

See also

EnableTrace
EnableTraceEx
EnableTraceEx2
ENABLE_TRACE_PARAMETERS
EVENT_FILTER_DESCRIPTOR

 

 