ONEX_RESULT_UPDATE_DATA structure
Applies to: desktop apps only
The ONEX_RESULT_UPDATE_DATA structure contains information on a status change to 802.1X authentication.
Syntax
typedef struct _ONEX_RESULT_UPDATE_DATA {
ONEX_STATUS oneXStatus;
ONEX_EAP_METHOD_BACKEND_SUPPORT BackendSupport;
BOOL fBackendEngaged;
DWORD fOneXAuthParams :1;
DWORD fEapError :1;
ONEX_VARIABLE_BLOB authParams;
ONEX_VARIABLE_BLOB eapError;
} ONEX_RESULT_UPDATE_DATA, *PONEX_RESULT_UPDATE_DATA;
Members
- oneXStatus
-
Specifies the current 802.1X authentication status. For more information, see the ONEX_STATUS structure.
- BackendSupport
-
Indicates if the configured EAP method on the supplicant is supported on the 802.1X authentication server.
EAP permits the use of a backend authentication server, which may implement some or all authentication methods, with the authenticator acting as a pass-through for some or all methods and peers. For more information, see RFC 3748 published by the IETF and the ONEX_EAP_METHOD_BACKEND_SUPPORT enumeration.
- fBackendEngaged
-
Indicates if a response was received from the 802.1X authentication server.
- fOneXAuthParams
-
Indicates if the ONEX_RESULT_UPDATE_DATA structure contains 802.1X authentication parameters in the authParams member.
- fEapError
-
Indicates if the ONEX_RESULT_UPDATE_DATA structure contains an EAP error in the eapError member.
- authParams
-
The 802.1X authentication parameters. This member contains an embedded ONEX_AUTH_PARAMS structure starting at the dwOffset member of the ONEX_VARIABLE_BLOB if the fOneXAuthParams bitfield member is set.
- eapError
-
An EAP error value. This member contains an embedded ONEX_EAP_ERROR structure starting at the dwOffset member of the ONEX_VARIABLE_BLOB if the fEapError bitfield member is set.
Remarks
The ONEX_RESULT_UPDATE_DATA structure is used by the 802.1X module, a new wireless configuration component supported on Windows Vista and later.
The ONEX_RESULT_UPDATE_DATA contains information on a status change to 802.1X authentication.This structure is returned when the NotificationSource member of the WLAN_NOTIFICATION_DATA structure is WLAN_NOTIFICATION_SOURCE_ONEX and the NotificationCode member of the WLAN_NOTIFICATION_DATA structure for received notification is OneXNotificationTypeResultUpdate. For this notification, the pData member of the WLAN_NOTIFICATION_DATA structure points to an ONEX_RESULT_UPDATE_DATA structure that contains information on the 802.1X authentication status change.
Requirements
|
Minimum supported client | Windows Vista |
|---|---|
|
Minimum supported server | Windows Server 2008 |
|
Header |
|
See also
- About the ACM Architecture
- ONEX_AUTH_PARAMS
- ONEX_EAP_ERROR
- ONEX_EAP_METHOD_BACKEND_SUPPORT
- ONEX_NOTIFICATION_TYPE
- ONEX_STATUS
- ONEX_VARIABLE_BLOB
- WLAN_NOTIFICATION_DATA
- WlanRegisterNotification
Send comments about this topic to Microsoft