The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

class MSFT_SIPPoolExtData
{
  [key] string Backend;
  [key] string InstanceID;
  string Name;
  string Value;
};

Methods

This class does not define any methods.

Properties

The MSFT_SIPPoolExtData class has the following properties.

Backend

Data type: [key] string

Access type: Read-only

Must be empty when accessing data from Edge Server or Proxy Server roles. Required when accessing data from any role that belongs to a pool.

The computer name (either the FQDN or NetBIOS name) and SQL Server instance name of the Office Communications Server 2007, back-end database (configuration data is stored in the same SQL instance as user data, but in a different database). Indicates where this class is stored, which varies depending on the server role.

Server Role

Acceptable Values

Enterprise Edition

SQL_Instance_Name

Standard Edition

(local)\rtc

Access Edge Server and Forwarding Proxy

Empty string

InstanceID

Data type: [key] string

Access type: Read-only

Optional. A GUID value that uniquely identifies an instance of this class.

The GUID must be encapsulated between the "{" and "}" braces; for example: "{01234567-0123-4567-89AB-CDEF01234567}".

Name

Data type: string

Access type: Read/Write

Required.

The value of this property is not case-sensitive.

The maximum length of the string is 64 characters.

Value

Data type: string

Access type: Read/Write

Optional.

The value of this property is not case-sensitive.

Remarks

This class gets and sets information at the following level(s): SQL.

Instances of this class support the following interface methods:

  • Provider::DeleteInstance();

  • Provider::EnumerateInstances();

  • Provider::GetObject();

  • Provider::PutInstance();

    Where PutInstance() supports the following flag(s):

    • WBEM_FLAG_CREATE_ONLY

    • WBEM_FLAG_UPDATE_ONLY

    • WBEM_FLAG_CREATE_OR_UPDATE

Requirements

Server: Installed on computers serving the following role(s): Administrative Tools Server, Audio/Video Conferencing Server, Front End Server, Web Components Server, Web Conferencing Server.

Namespace: Defined in \root\cimv2.