Export (0) Print
Expand All

SMS_Report Server WMI Class

System Center

Updated: October 28, 2009

Applies To: System Center Configuration Manager 2007, System Center Configuration Manager 2007 R2, System Center Configuration Manager 2007 R3, System Center Configuration Manager 2007 SP1, System Center Configuration Manager 2007 SP2

The SMS_Report Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a fully defined report that can be run by Configuration Manager Reports.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.


Class SMS_Report : SMS_BaseClass
{
      String Category;
      String Comment;
      UInt32 DrillThroughColumns[];
      UInt32 DrillThroughReportID;
      ref:SMS_Report DrillThroughReportPath;
      String DrillThroughURL;
      String GraphCaption;
      UInt32 GraphType;
      UInt32 GraphXCol;
      UInt32 GraphYCol;
      Boolean MachineDetail;
      Boolean MachineSource;
      String Name;
      UInt32 NumPrompts;
      UInt32 RefreshInterval;
      String ReportGUID;
      UInt32 ReportID;
      SMS_ReportParameter ReportParams[];
      String SecurityKey;
      String SQLQuery;
      Boolean StatusMessageDetailSource;
      Boolean UnicodeData;
      String XColLabel;
      String YColLabel;
};

The following table shows the methods in SMS_Report.

 

Method Description

GetReportPointInfo Method in Class SMS_Report

Gets report point information.

ValidateQuery Method in Class SMS_Report

Verifies that a report query is a valid SQL statement and performs the same level of validation that occurs when the report is saved.

Category
Data type: String

Access type: Read/Write

Qualifiers: None

Category to be used in the Configuration Manager console to filter the list of reports and to provide a report hierarchy. The default value is "".

Comment
Data type: String

Access type: Read/Write

Qualifiers: None

Further description of the report to be displayed on the property page for the report in the Configuration Manager console.

DrillThroughColumns
Data type: UInt32 Array

Access type: Read/Write

Qualifiers: None

Integers indicating the columns to use as the parameters of the destination report when drilling through on a particular row. If this property is not applicable, set it to null or an empty array.

DrillThroughReportID
Data type: UInt32

Access type: Read/Write

Qualifiers: None

Report ID to link to each row of the report. Selected columns from the originating report are used as parameters to the destination report. Set this property to null if there is no drill-through destination for the report.

This property can be set to a report object path to support references to other reports in the same MOF file as the originating report.

DrillThroughReportPath
Data type: SMS_Report REF

Access type: Read Only

Qualifiers: [lazy]

Relative path of the WMI object representing the destination report to which the originating report will drill through. When defining multiple reports in a MOF file that link together, set this property to the path alias from the previously defined drill-through report.

DrillThroughURL
Data type: String

Access type: Read/Write

Qualifiers: None

The URL of the drill-through report.

GraphCaption
Data type: String

Access type: Read/Write

Qualifiers: None

Caption for the report graph. If there is no graph, set this property to null.

GraphType
Data type: UInt32

Access type: Read/Write

Qualifiers: None

Type of report graph. Set this property to null if no graph is available.

GraphXCol
Data type: UInt32

Access type: Read/Write

Qualifiers: None

Column number to use for the X axis of the graph. Set this property to null if it is not applicable.

GraphYCol
Data type: UInt32

Access type: Read/Write

Qualifiers: None

Column number to use for the Y axis of the graph. Set this property to null if it is not applicable.

MachineDetail
Data type: Boolean

Access type: Read/Write

Qualifiers: None

true if the report is a computer detail report, having one parameter that represents the Name0 column of the report. The default value is false.

MachineSource
Data type: Boolean

Access type: Read/Write

Qualifiers: None

true if this report drills through to the computer details page. The DrillThroughColumns property should contain a single index representing the Name0 column of the report. The default value is false.

Name
Data type: String

Access type: Read/Write

Qualifiers: None

Report name to display in the Configuration Manager console and on the report itself.

NumPrompts
Data type: UInt32

Access type: Read/Write

Qualifiers: None

The number of report prompts allowed in the console.

RefreshInterval
Data type: UInt32

Access type: Read/Write

Qualifiers: [Range("0-60")]

The interval, in seconds, that should elapse before the report is automatically rerun and the page is refreshed. Possible values are 0 (default) through 60. Set this property to 0 if the page should not be automatically refreshed.

ReportGUID
Data type: String

Access type: Read/Write

Qualifiers: [unique]

GUID for the report.

ReportID
Data type: UInt32

Access type: Read/Write

Qualifiers: [key]

Unique automatically generated number that identifies the report.

ReportParams
Data type: SMS_ReportParameter Array

Access type: Read/Write

Qualifiers: [lazy]

SMS_ReportParameter Server WMI Class objects that define the user-supplied parameters to the report. Set this property to null or an empty array if there are no parameters.

SecurityKey
Data type: String

Access type: Read/Write

Qualifiers: [unique]

Unique automatically generated key used as the security identifier for the SMS_UserInstancePermissions Server WMI Class class.

SQLQuery
Data type: String

Access type: Read/Write

Qualifiers: [lazy, large]

Text of the SQL query that produces the result set of the report.

StatusMessageDetailSource
Data type: Boolean

Access type: Read/Write

Qualifiers: None

true if the source of the status message is detailed. The default value is false.

UnicodeData
Data type: Boolean

Access type: Read/Write

Qualifiers: None

true if the report includes Unicode data. The default value is false.

XColLabel
Data type: String

Access type: Read/Write

Qualifiers: None

Caption for the X axis of the graph. Set this property to null if it is not applicable.

YColLabel
Data type: String

Access type: Read/Write

Qualifiers: None

Caption for the Y axis of the graph. Set this property to null if it is not applicable.

Class qualifiers for this class include:

  • Secured

For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.

Runtime Requirements

Development Requirements

Show: