- AdditionalAvailability
-
- Data type: uint16 array
- Access type: Read-only
Additional availability and status of the device. This property is inherited from
CIM_LogicalDevice and is always set to 6 (Not
Applicable).
- Availability
-
- Data type: uint16
- Access type: Read-only
The primary availability and status of the device. This property is inherited from
CIM_LogicalDevice but is not used.
- Caption
-
- Data type: string
- Access type: Read-only
A short textual description (one- line string) of the object. This property is inherited from
CIM_ManagedElement and is always set to
"Shutdown".
- CreationClassName
-
- Data type: string
- Access type: Read-only
The scoping system's creation class name. This property is inherited from
CIM_LogicalDevice and is always set to
"Msvm_ShutdownComponent".
- Description
-
- Data type: string
- Access type: Read-only
A textual description of the object. This property is inherited from
CIM_ManagedElement and is always set to
"Microsoft Shutdown Service".
- DeviceID
-
- Data type: string
- Access type: Read-only
An address or other identifying information to uniquely name the LogicalDevice. This property is inherited
from CIM_LogicalDevice and is always set to
"Microsoft:VMGUID\GUID" where
VMGUID is the Name property of the
Msvm_ComputerSystem instance associated with
this device.
- ElementName
-
- Data type: string
- Access type: Read-only
A user-friendly name for the object. This property is inherited from
CIM_ManagedElement and it is set to
"Shutdown".
- EnabledDefault
-
- Data type: uint16
- Access type: Read-only
This property is inherited from
CIM_EnabledLogicalElement and is always
set to 7 (No Default).
- EnabledState
-
- Data type: uint16
- Access type: Read-only
The enabled and disabled states of an element. This property is inherited from
CIM_EnabledLogicalElement and is either
set to 2 (Enabled) or 3 (Disabled).
- ErrorCleared
-
- Data type: boolean
- Access type: Read-only
Indicates whether the error reported in the
LastErrorCode property is now cleared. This property is inherited from
CIM_LogicalDevice but is not used.
- ErrorDescription
-
- Data type: string
- Access type: Read-only
A free-form string that provides more information about the error recorded in the
LastErrorCode property, and information on any corrective actions that may be
taken. This property is inherited from
CIM_LogicalDevice but is not used.
- HealthState
-
- Data type: uint16
- Access type: Read-only
The current health of the element. This property is inherited from
CIM_ManagedSystemElement and is always set
to 5 (OK).
- IdentifyingDescriptions
-
- Data type: string array
- Access type: Read-only
An array of free-form strings that provide explanations and details behind the entries in the
OtherIdentifyingInfo array. This property is inherited from
CIM_LogicalDevice but is not used.
- InstallDate
-
- Data type: datetime
- Access type: Read-only
The date and time that the integration component was installed into the virtual system. This property is
inherited from CIM_ManagedSystemElement.
- LastErrorCode
-
- Data type: uint32
- Access type: Read-only
The last error code reported by the logical device. This property is inherited from
CIM_LogicalDevice but is not used.
- LocationIndicator
-
- Data type: uint16
- Access type: Read-only
The state of an indicator that is part of a device. This property is inherited from
CIM_LogicalDevice and it is always set to 4 (Not
Supported).
- MaxQuiesceTime
-
- Data type: uint64
- Access type: Read-only
This property is inherited from
CIM_LogicalDevice but is not used.
- Name
-
- Data type: string
- Access type: Read-only
The label by which the object is known. This property is inherited from
CIM_ManagedSystemElement and is always set
to "Shutdown".
- OperationalStatus
-
- Data type: uint16 array
- Access type: Read-only
The current status of the element. This property is inherited from
CIM_ManagedSystemElement.
Windows Server 2008: The
OperationalStatus[0] property is always set to 2 (OK).
The following are the possible values for the OperationalStatus[0]
property value.
| Value | Meaning |
- OK
- 2
| The component is operating normally. The OperationalStatus[1] and
StatusDescriptions[1] property values may contain more information.
|
- Degraded
- 3
| The component is operating normally but the guest component negotiated a compatible communications
protocol version. The OperationalStatus[1] and
StatusDescriptions[1] property values may contain more information.
|
- Non-Recoverable Error
- 7
| The guest does not support a compatible protocol version. The
OperationalStatus[1] and
StatusDescriptions[1] property values may contain more information.
|
- No Contact
- 12
| The guest component is not installed or has not yet been contacted.
|
- Lost Communication
- 13
| The guest component is no longer responding normally.
|
- OtherEnabledState
-
- Data type: string
- Access type: Read-only
A string that describes the enabled or disabled state of the element when the
EnabledState property is set to 1 (Other). This property must be set to
NULL when the EnabledState property is any value
other than 1. This property is inherited from
CIM_EnabledLogicalElement and is always
set to NULL.
- OtherIdentifyingInfo
-
- Data type: string array
- Access type: Read-only
Any additional data, beyond device ID information, that could be used to identify a logical device. This
property is inherited from CIM_LogicalDevice and
is always set to NULL.
- PoweManagementCapabilities
-
- Data type: uint16 array
- Access type: Read-only
The power management capabilities of the device. This property is inherited from
CIM_LogicalDevice but is not used.
- PowerManagementSupported
-
- Data type: boolean
- Access type: Read-only
Indicates whether the device can be power managed. This property is inherited from
CIM_LogicalDevice but is not used.
- PowerOnHours
-
- Data type: uint64
- Access type: Read-only
The number of consecutive hours that this Device has been powered on, since its last power cycle. This
property is inherited from CIM_LogicalDevice but
is not used.
- RequestedState
-
- Data type: uint16
- Access type: Read-only
The last requested or desired state for the element. This property is inherited from
CIM_EnabledLogicalElement and is always
set to 12 (Not Applicable).
- Status
-
- Data type: string
- Access type: Read-only
The current status of the object. This property is inherited from
CIM_ManagedSystemElement but is not
used.
- StatusDescriptions
-
- Data type: string array
- Access type: Read-only
Strings that describe the various OperationalStatus array
values. This property is inherited from
CIM_ManagedSystemElement.
Windows Server 2008: The
OperationalStatus[0] property value is always set to
"OK" before Windows Server 2008 R2.
- StatusInfo
-
- Data type: uint16
- Access type: Read-only
The current state of the logical device. This property is inherited from
CIM_LogicalDevice but is not used.
- SystemCreationClassName
-
- Data type: string
- Access type: Read-only
The scoping system's creation class name. This property is inherited from
CIM_LogicalDevice and is always set to
"Msvm_ComputerSystem".
- SystemName
-
- Data type: string
- Access type: Read-only
The scoping system's name. This property is inherited from
CIM_LogicalDevice and is the
Name property of the
Msvm_ComputerSystem instance associated with
this heartbeat component.
- TimeOfLastStateChange
-
- Data type: datetime
- Access type: Read-only
The date or time when the enabled state of the element last changed. This property is inherited from
CIM_EnabledLogicalElement and is always
set to NULL.
- TotalPowerOnHours
-
- Data type: uint64
- Access type: Read-only
The total number of hours that this device has been powered. This property is inherited from
CIM_LogicalDevice but is not used.