CIM_LogicalPort class

The abstraction of a port or connection point of a device. This object should be instantiated when the port has independent management characteristics from the device that includes it. Examples are a Fibre Channel Port and a USB Port.

Important  The DMTF (Distributed Management Task Force) CIM (Common Information Model) classes are the parent classes upon which WMI classes are built. WMI currently supports only the CIM 2.x version schemas.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.

Syntax

class CIM_LogicalPort : CIM_LogicalDevice
{
  string   SystemName;
  string   SystemCreationClassName;
  uint16   StatusInfo;
  string   Status;
  boolean  PowerManagementSupported;
  uint16   PowerManagementCapabilities[];
  string   PNPDeviceID;
  string   Name;
  uint32   LastErrorCode;
  datetime InstallDate;
  string   ErrorDescription;
  boolean  ErrorCleared;
  string   DeviceID;
  string   Description;
  string   CreationClassName;
  boolean  ConfigManagerUserConfig;
  uint32   ConfigManagerErrorCode;
  string   Caption;
  uint16   Availability;
  uint64   Speed;
  uint64   MaxSpeed;
  uint64   RequestedSpeed;
  uint16   UsageRestriction;
  uint16   PortType;
  string   OtherPortType;
};

Members

The CIM_LogicalPort class has these types of members:

Properties

The CIM_LogicalPort class has these properties.

Availability
Data type: uint16
Access type: Read-only

Availability and status of the device. Inherited from CIM_LogicalDevice.

ValueMeaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

Running/Full Power

4 (0x4)

Warning

5 (0x5)

In Test

6 (0x6)

Not Applicable

7 (0x7)

Power Off

8 (0x8)

Off Line

9 (0x9)

Off Duty

10 (0xA)

Degraded

11 (0xB)

Not Installed

12 (0xC)

Install Error

13 (0xD)

Power Save - Unknown

The device is known to be in a power save mode, but its exact status is unknown.

14 (0xE)

Power Save - Low Power Mode

The device is in a power save state but still functioning, and may exhibit degraded performance.

15 (0xF)

Power Save - Standby

The device is not functioning but could be brought to full power quickly.

16 (0x10)

Power Cycle

17 (0x11)

Power Save - Warning

The device is in a warning state, though also in a power save mode.

 

Caption
Data type: string
Access type: Read-only

Short textual description of the object. This property is inherited from CIM_ManagedSystemElement.

ConfigManagerErrorCode
Data type: uint32
Access type: Read-only

Win32 Configuration Manager error code.

ValueMeaning
0 (0x0)

Device is working properly.

1 (0x1)

Device is not configured correctly.

2 (0x2)

Windows cannot load the driver for this device.

3 (0x3)

Driver for this device might be corrupted, or the system may be low on memory or other resources.

4 (0x4)

Device is not working properly. One of its drivers or the registry might be corrupted.

5 (0x5)

Driver for the device requires a resource that Windows cannot manage.

6 (0x6)

Boot configuration for the device conflicts with other devices.

7 (0x7)

Cannot filter.

8 (0x8)

Driver loader for the device is missing.

9 (0x9)

Device is not working properly; the controlling firmware is incorrectly reporting the resources for the device.

10 (0xA)

Device cannot start.

11 (0xB)

Device failed.

12 (0xC)

Device cannot find enough free resources to use.

13 (0xD)

Windows cannot verify the device's resources.

14 (0xE)

Device cannot work properly until the computer is restarted.

15 (0xF)

Device is not working properly due to a possible re-enumeration problem.

16 (0x10)

Windows cannot identify all of the resources that the device uses.

17 (0x11)

Device is requesting an unknown resource type.

18 (0x12)

Device drivers must be reinstalled.

19 (0x13)

Failure using the VxD loader.

20 (0x14)

Registry might be corrupted.

21 (0x15)

System failure. If changing the device driver is ineffective, see the hardware documentation. Windows is removing the device.

22 (0x16)

Device is disabled.

23 (0x17)

System failure. If changing the device driver is ineffective, see the hardware documentation.

24 (0x18)

Device is not present, not working properly, or does not have all of its drivers installed.

25 (0x19)

Windows is still setting up the device.

26 (0x1A)

Windows is still setting up the device.

27 (0x1B)

Device does not have valid log configuration.

28 (0x1C)

Device drivers are not installed.

29 (0x1D)

Device is disabled; the device firmware did not provide the required resources.

30 (0x1E)

Device is using an IRQ resource that another device is using.

31 (0x1F)

Device is not working properly; Windows cannot load the required device drivers.

 

ConfigManagerUserConfig
Data type: boolean
Access type: Read-only

If TRUE, the device is using a user-defined configuration.

CreationClassName
Data type: string
Access type: Read-only

Name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified.

Description
Data type: string
Access type: Read-only

Textual description of the object. This property is inherited from CIM_ManagedSystemElement.

DeviceID
Data type: string
Access type: Read-only

Address or other identifying information to uniquely name the logical device.

ErrorCleared
Data type: boolean
Access type: Read-only

If TRUE, the error reported in the LastErrorCode property is now cleared.

ErrorDescription
Data type: string
Access type: Read-only

Free-form string that supplies information about the error recorded in the LastErrorCode property and corrective actions to perform.

InstallDate
Data type: datetime
Access type: Read-only

Date and time the object was installed. This property does not require a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.

LastErrorCode
Data type: uint32
Access type: Read-only

Last error code reported by the logical device.

MaxSpeed
Data type: uint64
Access type: Read-only
Qualifiers: Units ( "Bits per Second" )

The maximum bandwidth, in bits per second, of the port.

Name
Data type: string
Access type: Read-only

Label by which the object is known. When subclassed, this property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement.

OtherPortType
Data type: string
Access type: Write-only

Describes the type of module, when PortType is set to 1 ("Other").

PNPDeviceID
Data type: string
Access type: Read-only

Indicates the Win32 Plug and Play device identifier of the logical device.

Example: "*PNP030b"

PortType
Data type: uint16
Access type: Write-only

Forces consistent naming of the 'type' property in subclasses and to guarantee unique enum values for all instances of NetworkPort. When set to 1 ("Other"), related property OtherPortType contains a string description of the type of port. A range of values, DMTF_Reserved, has been defined that allows subclasses to override and define their specific types of ports.

Unknown (0)
Other (1)
Not Applicable (2)
DMTF Reserved (3..15999)
Vendor Reserved (16000..65535)
PowerManagementCapabilities
Data type: uint16 array
Access type: Read-only

Array of the specific power-related capabilities of a logical device. This property is inherited from CIM_LogicalDevice.

ValueMeaning
0 (0x0)

Unknown

1 (0x1)

Not Supported

2 (0x2)

Disabled

3 (0x3)

Enabled

The power management features are currently enabled, but the exact feature set is unknown or the information is unavailable.

4 (0x4)

Power Saving Modes Entered Automatically

The device can change its power state based on usage or other criteria.

5 (0x5)

Power State Settable

The SetPowerState method is supported. This method is found on the parent CIM_LogicalDevice class and can be implemented. For more information, see Designing Managed Object Format (MOF) Classes.

6 (0x6)

Power Cycling Supported

The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle).

7 (0x7)

Timed Power On Supported

The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle) and Time set to a specific date and time, or interval, for power-on.

 

PowerManagementSupported
Data type: boolean
Access type: Read-only

If TRUE, the device can be power managed, that is, put into a power-save state. If FALSE, the integer value 1 ("Not Supported") should be the only entry in the PowerManagementCapabilities array.

This property does not indicate whether power management features are currently enabled, or if enabled, which features are supported. For more information, see the PowerManagementCapabilities array.

RequestedSpeed
Data type: uint64
Access type: Write-only
Qualifiers: Units ( "Bits per Second" )

The requested bandwidth, in bits per second, of the port. The actual bandwidth is reported in the Speed property.

Speed
Data type: uint64
Access type: Read-only
Qualifiers: Units ( "Bits per Second" )

The bandwidth, in bits per second, of the port.

Status
Data type: string
Access type: Read-only

Current status of the object. This property is inherited from CIM_ManagedSystemElement.

Values include the following:

"OK"
"Error"
"Degraded"
"Unknown"
"Pred Fail"
"Starting"
"Stopping"
"Service"
"Stressed"
"NonRecover"
"No Contact"
"Lost Comm"
StatusInfo
Data type: uint16
Access type: Read-only

State of the logical device. If this property does not apply to the logical device, the value 5 (Not Applicable) should be used. This property is inherited from CIM_LogicalDevice.

ValueMeaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

Enabled

4 (0x4)

Disabled

5 (0x5)

Not Applicable

 

SystemCreationClassName
Data type: string
Access type: Read-only

Scoping system's creation class name.

SystemName
Data type: string
Access type: Read-only

Scoping system's name.

UsageRestriction
Data type: uint16
Access type: Write-only

In some cases, a logical port might be identifiable as a front end or back end port. An example of this situation would be a storage array that might have back end ports to communicate with disk drives and front end ports to communicate with hosts. If there is no restriction on the use of the port, then the value should be set to 'not restricted'.

Unknown (0)
Front-end only (2)
Back-end only (3)
Not restricted (4)

Requirements