Based on the specified delimiter set, no valid Time value could be generated

Details

 

Product Name

BizTalk Server

Product Version

3.6

Event ID

-

Event Source

BizTalk Server EDI

Component

EDI Engine

Symbolic Name

-

Message Text

Based on the specified delimiter set, no valid Time value could be generated. Please use another delimiter set.

Explanation

This Error/Warning/Information event indicates that the EDI send pipeline could not generate a valid time value because a character used in a time field of the outgoing interchange was the same as a separator character.

User Action

To resolve this error, change the separator values used by the EDI send pipeline to create a message so that no separator character is the same as a character used in a time field. Do one of the following:

  • For an X12 interchange being sent to a resolved party, change the separator settings in the ISA Segment Definition page for the party as interchange receiver.

  • For an X12 interchange being sent to a party that has not been resolved, change the separator settings in the ISA Segment Definition global property page.

  • For an EDIFACT interchange being sent to a resolved party, change the separator settings in the UNA Segment Definition page for the party as interchange receiver.

  • For an EDIFACT interchange being sent to a party that has not been resolved, change the separator settings in the UNA Segment Definition global property page.