Group control number violates syntax

Details

Field Error Details
Product Name BizTalk Server
Product Version 3.9
Event ID -
Event Source BizTalk Server EDI
Component EDI Engine
Symbolic Name X12FaInvalidControlNumberDescription
Message Text Group control number violates syntax

Explanation

This Error/Warning/Information event indicates that the receive pipeline could not process the incoming X12 interchange because the group control number in the GS06 and GE02 fields of the interchange did not conform to the data type or length specified in the service schema. The service schema is the X12ServiceSchema in BaseArtifacts.dll.

User Action

To resolve this error, make sure that the group control numbers contained in the GS06 and GE02 fields of the interchange conform to the data type (X12_N0) and length (between one and nine digits) specified in the service schema, and then have the interchange resent.