A failure occurred in processing Edifact message on send port: No agreement for receiver and sender identifier-qualifier pairs
Details
Field | Error Details |
---|---|
Product Name | BizTalk Server |
Product Version | 3.9 |
Event ID | - |
Event Source | BizTalk Server EDI |
Component | EDI Engine |
Symbolic Name | - |
Message Text | A failure occurred in processing Edifact message on send port {0}. No agreement exists for receiver and sender identifier/qualifier pairs for {1}, {2}, {3}, {4}. |
Explanation
This Error/Warning/Information event indicates BizTalk Server was unable to resolve the party for the EDIFACT interchange because it was unable to match promoted sender qualifier and identifier properties, and promoted receiver qualifier and identifier properties, with the corresponding values for a party.
User Action
To resolve this error, ensure that the sender qualifier and identifier (UNB2.1 and UNB2.2) and receiver qualifier and identifier (UNB3.1 and UNB3.2) defined in the party's UNB Segment Definition page of the EDI Properties dialog box match the corresponding promoted properties in the context of the interchange.