This topic has not yet been rated - Rate this topic

How to Configure the Flat File Disassembler Pipeline Component

The Flat File Disassembler pipeline component is used for disassembling documents in flat file format and converting them into XML format.

To configure the properties for the Flat File Disassembler pipeline component

  1. Drag the Flat File Disassembler pipeline component into the Disassemble stage of a receive pipeline.

  2. In the Properties window, in the Pipeline Component Properties section, do the following.

     

    Use this To do this

    Document schema

    Select a flat file document schema to use for parsing the message from flat file to XML format. The flat file document schema for parsing can be created in BizTalk Editor.

    Default value: None

    noteNote
    You must specify a schema for this property, or a compile-time error will occur.

    Header schema

    Select a schema for the header part of the flat file message. The schema for the header part of the flat file message can be created in BizTalk Editor.

    Default value: None

    Preserve header

    Set this property to True if you need to store the flat file message header on the message context. Preserving the header of the flat file message enables the header structure and content to flow with the message through BizTalk Server. The header can then be used when serializing the message back to flat file format in the Flat File Assembler pipeline component.

    When the preserved header is being serialized by the Flat File Assembler, the header document design-time property can lack the name of the header schema, because this information can be obtained dynamically at run time. This is accomplished by using the message type of the preserved header.

    Default value: False

    Trailer schema

    Select a schema for the trailer part of the flat file message. The schema for the trailer part of the flat file message can be created in BizTalk Editor.

    Default value: None

    Recoverable interchange processing

    When "false" - indicates that entire interchange is disassembled as a unit (if any contained message fails, entire interchange is suspended).

    When "true" - indicates that messages within interchange are extracted individually by disassembler with possibility of some propagating through messaging pathway and others being suspended.

    For more information on recoverable interchange processing, see Recoverable Interchange Processing.

    Validate document structure

    Set this property to True if you need to validate all the parts of the flat file message (header, body, and trailer) to make sure they conform to their schemas. This option reduces the performance of the Flat File Disassembler, so it is set to False by default.

    Default value: False

See Also

  © 2009 Microsoft Corporation. All rights reserved.
Did you find this helpful?