Win32_POTSModem class

The Win32_POTSModem WMI class represents the services and characteristics of a Plain Old Telephone Service (POTS) modem on a computer system running Windows.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties. Properties are listed in alphabetic order, not MOF order.

Syntax

[Provider("CIMWin32")]class Win32_POTSModem : CIM_PotsModem
{
  uint16   AnswerMode;
  string   AttachedTo;
  uint16   Availability;
  string   BlindOff;
  string   BlindOn;
  string   Caption;
  string   CompatibilityFlags;
  uint16   CompressionInfo;
  string   CompressionOff;
  string   CompressionOn;
  uint32   ConfigManagerErrorCode;
  boolean  ConfigManagerUserConfig;
  string   ConfigurationDialog;
  string   CountriesSupported[];
  string   CountrySelected;
  string   CreationClassName;
  string   CurrentPasswords[];
  uint8    DCB[];
  uint8    Default[];
  string   Description;
  string   DeviceID;
  string   DeviceLoader;
  string   DeviceType;
  uint16   DialType;
  datetime DriverDate;
  boolean  ErrorCleared;
  string   ErrorControlForced;
  uint16   ErrorControlInfo;
  string   ErrorControlOff;
  string   ErrorControlOn;
  string   ErrorDescription;
  string   FlowControlHard;
  string   FlowControlOff;
  string   FlowControlSoft;
  string   InactivityScale;
  uint32   InactivityTimeout;
  uint32   Index;
  datetime InstallDate;
  uint32   LastErrorCode;
  uint32   MaxBaudRateToPhone;
  uint32   MaxBaudRateToSerialPort;
  uint16   MaxNumberOfPasswords;
  string   Model;
  string   ModemInfPath;
  string   ModemInfSection;
  string   ModulationBell;
  string   ModulationCCITT;
  uint16   ModulationScheme;
  string   Name;
  string   PNPDeviceID;
  string   PortSubClass;
  uint16   PowerManagementCapabilities[];
  boolean  PowerManagementSupported;
  string   Prefix;
  uint8    Properties[];
  string   ProviderName;
  string   Pulse;
  string   Reset;
  string   ResponsesKeyName;
  uint8    RingsBeforeAnswer;
  string   SpeakerModeDial;
  string   SpeakerModeOff;
  string   SpeakerModeOn;
  string   SpeakerModeSetup;
  string   SpeakerVolumeHigh;
  uint16   SpeakerVolumeInfo;
  string   SpeakerVolumeLow;
  string   SpeakerVolumeMed;
  string   Status;
  uint16   StatusInfo;
  string   StringFormat;
  boolean  SupportsCallback;
  boolean  SupportsSynchronousConnect;
  string   SystemCreationClassName;
  string   SystemName;
  string   Terminator;
  datetime TimeOfLastReset;
  string   Tone;
  string   VoiceSwitchFeature;
};

Members

The Win32_POTSModem class has these types of members:

Methods

The Win32_POTSModem class has these methods.

MethodDescription
Reset

Not implemented. To implement this method, see the Reset method in CIM_PotsModem.

SetPowerState

Not implemented. To implement this method, see the SetPowerState method in CIM_PotsModem.

 

Properties

The Win32_POTSModem class has these properties.

AnswerMode
Data type: uint16
Access type: Read-only

Current auto-answer or callback setting for the modem. This property is inherited from CIM_PotsModem.

ValueMeaning
1

Unknown

2

Other

3

Disabled

4

Manual Answer

5

Auto Answer

6

Auto Answer with Callback

 

AttachedTo
Data type: string
Access type: Read-only

Port to which the POTS modem is attached.

Example: "COM1"

Availability
Data type: uint16
Access type: Read-only

Availability and status of the device. Inherited from CIM_LogicalDevice.

ValueMeaning
1 (0x1)

Other

2 (0x2)

Unknown

3 (0x3)

Running or Full Power

4 (0x4)

Warning

5 (0x5)

In Test

6 (0x6)

Not Applicable

7 (0x7)

Power Off

8 (0x8)

Off Line

9 (0x9)

Off Duty

10 (0xA)

Degraded

11 (0xB)

Not Installed

12 (0xC)

Install Error

13 (0xD)

Power Save - Unknown

The device is known to be in a power save mode, but its exact status is unknown.

14 (0xE)

Power Save - Low Power Mode

The device is in a power save state but still functioning, and may exhibit degraded performance.

15 (0xF)

Power Save - Standby

The device is not functioning, but could be brought to full power quickly.

16 (0x10)

Power Cycle

17 (0x11)

Power Save - Warning

The device is in a warning state, though also in a power save mode.

 

BlindOff
Data type: string
Access type: Read-only

Command string used to detect a dial tone before dialing.

Example: "X4"

BlindOn
Data type: string
Access type: Read-only

Command string used to dial whether or not there is a dial tone.

Example: "X3"

Caption
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64)

Short description of the object. This property is inherited from CIM_ManagedSystemElement.

CompatibilityFlags
Data type: string
Access type: Read-only

All modem connection protocols with which this modem device is compatible.

CompressionInfo
Data type: uint16
Access type: Read-only

Data compression characteristics of the modem. This property is inherited from CIM_PotsModem.

ValueMeaning
1

Unknown

2

Other

3

No Compression

4

MNP 5

5

V.42bis

 

CompressionOff
Data type: string
Access type: Read-only

Command string used to disable hardware data compression.

Example: "S46=136"

CompressionOn
Data type: string
Access type: Read-only

Command string used to enable hardware data compression.

Example: "S46=138"

ConfigManagerErrorCode
Data type: uint32
Access type: Read-only

Win32 Configuration Manager error code.

ValueMeaning
0 (0x0)

Device is working properly.

1 (0x1)

Device is not configured correctly.

2 (0x2)

Windows cannot load the driver for this device.

3 (0x3)

Driver for this device might be corrupted, or the system may be low on memory or other resources.

4 (0x4)

Device is not working properly. One of its drivers or the registry might be corrupted.

5 (0x5)

Driver for the device requires a resource that Windows cannot manage.

6 (0x6)

Boot configuration for the device conflicts with other devices.

7 (0x7)

Cannot filter.

8 (0x8)

Driver loader for the device is missing.

9 (0x9)

Device is not working properly. The controlling firmware is incorrectly reporting the resources for the device.

10 (0xA)

Device cannot start.

11 (0xB)

Device failed.

12 (0xC)

Device cannot find enough free resources to use.

13 (0xD)

Windows cannot verify the device's resources.

14 (0xE)

Device cannot work properly until the computer is restarted.

15 (0xF)

Device is not working properly due to a possible re-enumeration problem.

16 (0x10)

Windows cannot identify all of the resources that the device uses.

17 (0x11)

Device is requesting an unknown resource type.

18 (0x12)

Device drivers must be reinstalled.

19 (0x13)

Failure using the VxD loader.

20 (0x14)

Registry might be corrupted.

21 (0x15)

System failure. If changing the device driver is ineffective, see the hardware documentation. Windows is removing the device.

22 (0x16)

Device is disabled.

23 (0x17)

System failure. If changing the device driver is ineffective, see the hardware documentation.

24 (0x18)

Device is not present, not working properly, or does not have all of its drivers installed.

25 (0x19)

Windows is still setting up the device.

26 (0x1A)

Windows is still setting up the device.

27 (0x1B)

Device does not have valid log configuration.

28 (0x1C)

Device drivers are not installed.

29 (0x1D)

Device is disabled. The device firmware did not provide the required resources.

30 (0x1E)

Device is using an IRQ resource that another device is using.

31 (0x1F)

Device is not working properly. Windows cannot load the required device drivers.

 

ConfigManagerUserConfig
Data type: boolean
Access type: Read-only

If TRUE, the device is using a user-defined configuration. This property is inherited from CIM_LogicalDevice.

ConfigurationDialog
Data type: string
Access type: Read-only

Modem initialization string. This property is made up of command strings from other properties of this class.

CountriesSupported
Data type: string array
Access type: Read-only

Array of countries/regions in which the modem can operate. This property is inherited from CIM_PotsModem.

CountrySelected
Data type: string
Access type: Read-only

Country/region for which the modem is currently programmed. When multiple countries/regions are supported, this property defines which one is currently selected for use. This property is inherited from CIM_PotsModem.

CreationClassName
Data type: string
Access type: Read-only

Name of the first concrete class to appear in the inheritance chain used in the creation of an instance. When used with the other key properties of the class, the property allows all instances of this class and its subclasses to be uniquely identified. This property is inherited from CIM_LogicalDevice.

CurrentPasswords
Data type: string array
Access type: Read-only

List of currently defined passwords for the modem. This array may be left blank for security reasons. This property is inherited from CIM_PotsModem.

DCB
Data type: uint8 array
Access type: Read-only

Control settings for a serial communications device, in this case, the modem device.

Default
Data type: uint8 array
Access type: Read-only

If TRUE, this POTS modem is the default modem on the computer system running Windows.

Description
Data type: string
Access type: Read-only

Description of the object. This property is inherited from CIM_ManagedSystemElement.

DeviceID
Data type: string
Access type: Read-only
Qualifiers: Key

Unique identifier of this POTS modem from other devices on the system. This property is inherited from CIM_LogicalDevice.

DeviceLoader
Data type: string
Access type: Read-only

Name of the device loader for the modem. A device loader loads and manages device drivers and enumerators for a given device.

DeviceType
Data type: string
Access type: Read-only

Physical type of the modem.

The values are:

"Null Modem"
"Internal Modem"
"External Modem"
"PCMCIA Modem"
"Unknown"
DialType
Data type: uint16
Access type: Read-only

Type of dialing method used. This property is inherited from CIM_PotsModem.

ValueMeaning
0

Unknown

1

Tone

2

Pulse

 

DriverDate
Data type: datetime
Access type: Read-only

Date of the modem driver.

ErrorCleared
Data type: boolean
Access type: Read-only

If TRUE, the error reported in LastErrorCode is now cleared. This property is inherited from CIM_LogicalDevice.

ErrorControlForced
Data type: string
Access type: Read-only

Command string used to enable error correction control when establishing a connection. This increases the reliability of the connection.

Example: "+Q5S36=4S48=7"

ErrorControlInfo
Data type: uint16
Access type: Read-only

Error correction characteristics of the modem. This property is inherited from CIM_PotsModem.

ValueMeaning
1

Unknown

2

Other

3

No Error Correction

4

MNP 4

5

LAPM

 

ErrorControlOff
Data type: string
Access type: Read-only

Command string used to disable error control.

Example: "+Q6S36=3S48=128"

ErrorControlOn
Data type: string
Access type: Read-only

Command string used to enable error control.

Example: "+Q5S36=7S48=7"

ErrorDescription
Data type: string
Access type: Read-only

More information about the error recorded in LastErrorCode, and information on any corrective actions that may be taken. This property is inherited from CIM_LogicalDevice.

FlowControlHard
Data type: string
Access type: Read-only

Command string used to enable hardware flow control. Flow control consists of signals sent between computers that verify that both computers are ready to transmit or receive data.

Example: "&K1"

FlowControlOff
Data type: string
Access type: Read-only

Command string used to disable flow control. Flow control consists of signals sent between computers that verify that both computers are ready to transmit or receive data.

Example: "&K0"

FlowControlSoft
Data type: string
Access type: Read-only

Command string used to enable software flow control. Flow control consists of signals sent between computers that verify that both computers are ready to transmit or receive data.

Example: "&K2"

InactivityScale
Data type: string
Access type: Read-only

Multiplier used with the InactivityTimeout property to calculate the timeout period of a connection.

InactivityTimeout
Data type: uint32
Access type: Read-only
Qualifiers: Units (Seconds)

Time limit (in seconds) for automatic disconnection of the phone line, if no data is exchanged. A value of 0 (zero) indicates that this feature is present but not enabled. This property is inherited from CIM_PotsModem.

Index
Data type: uint32
Access type: Read-only

Index number for this POTS modem.

Example: 0

InstallDate
Data type: datetime
Access type: Read-only

Date and time the object was installed. This property does not need a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.

LastErrorCode
Data type: uint32
Access type: Read-only

Last error code reported by the logical device. This property is inherited from CIM_LogicalDevice.

MaxBaudRateToPhone
Data type: uint32
Access type: Read-only
Qualifiers: Units (Bits per second)

Maximum settable communication speed for accessing the phone system. This property is inherited from CIM_PotsModem.

MaxBaudRateToSerialPort
Data type: uint32
Access type: Read-only
Qualifiers: Units (Bits per second)

Maximum settable communication speed to the COM port for an external modem. Enter 0 (zero) if not applicable. This property is inherited from CIM_PotsModem.

MaxNumberOfPasswords
Data type: uint16
Access type: Read-only

Number of passwords definable in the modem itself. If this feature is not supported, enter 0 (zero). This property is inherited from CIM_PotsModem.

Model
Data type: string
Access type: Read-only

Model of this POTS modem.

Example: "Sportster 56K External"

ModemInfPath
Data type: string
Access type: Read-only

Path to this modem's .inf file. This file contains initialization information for the modem and its driver.

Example: "C:\WINNT\INF"

ModemInfSection
Data type: string
Access type: Read-only

Name of the section in the modem's .inf file that contains information about the modem.

ModulationBell
Data type: string
Access type: Read-only

Command string used to instruct the modem to use Bell modulations for 300 and 1200 bps.

Example: "B1"

ModulationCCITT
Data type: string
Access type: Read-only

Command string used to instruct the modem to use CCITT modulations for 300 and 1200 bps.

Example: "B0"

ModulationScheme
Data type: uint16
Access type: Read-only

Modulation scheme of the modem. This property is inherited from CIM_PotsModem.

ValueMeaning
1

Unknown

2

Other

3

Not Supported

4

Bell 103

5

Bell 212A

6

V.22bis

7

V.32

8

V.32bis

9

V.turbo

10

V.FC

11

V.34

12

V.34bis

 

Name
Data type: string
Access type: Read-only

Label by which the object is known. When subclassed, the property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement.

PNPDeviceID
Data type: string
Access type: Read-only

Windows Plug and Play device identifier of the logical device. This property is inherited from CIM_LogicalDevice.

Example: "*PNP030b"

PortSubClass
Data type: string
Access type: Read-only

Definition of the port used for this modem.

ValueMeaning
"00"

Parallel Port

"01"

Serial Port

"02"

Modem

 

PowerManagementCapabilities
Data type: uint16 array
Access type: Read-only

Array of the specific power-related capabilities of a logical device. This property is inherited from CIM_LogicalDevice.

ValueMeaning
0 (0x0)

Unknown

1 (0x1)

Not Supported

2 (0x2)

Disabled

3 (0x3)

Enabled

The power management features are currently enabled but the exact feature set is unknown or the information is unavailable.

4 (0x4)

Power Saving Modes Entered Automatically

The device can change its power state based on usage or other criteria.

5 (0x5)

Power State Settable

The SetPowerState method is supported. This method is found on the parent CIM_LogicalDevice class and can be implemented. For more information, see Designing Managed Object Format (MOF) Classes.

6 (0x6)

Power Cycling Supported

The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle).

7 (0x7)

Timed Power-On Supported

The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle) and Time set to a specific date and time, or interval, for power-on.

 

PowerManagementSupported
Data type: boolean
Access type: Read-only

If TRUE, the device can be power-managed (can be put into suspend mode, and so on). The property does not indicate that power management features are currently enabled, only that the logical device is capable of power management. This property is inherited from CIM_LogicalDevice.

Prefix
Data type: string
Access type: Read-only

Dialing prefix used to access an outside line.

Properties
Data type: uint8 array
Access type: Read-only

List of all the properties (and their values) for this modem.

ProviderName
Data type: string
Access type: Read-only

Network path to the computer that provides the modem services.

Pulse
Data type: string
Access type: Read-only

Command string used to instruct the modem to use pulse mode for dialing. Pulse dialing is necessary for phone lines that are unable to handle tone dialing.

Example: "P"

Reset
Data type: string
Access type: Read-only

Command string used to reset the modem for the next call.

Example: "AT&F"

ResponsesKeyName
Data type: string
Access type: Read-only

Response this modem might report to the operating system during the connection process. The first two characters specify the type of response. The second two characters specify information about the connection being made. The second two characters are used only for Negotiation Progress or Connect response codes. The next eight characters specify the modem-to-modem line speed negotiated in bits per second (bps). The characters represent a 32-bit unsigned long integer format (byte and word reversed). The last eight characters indicate that the modem is changing to a different port or Data Terminal Equipment (DTE) speed. Usually this field is not used because modems make connections at a locked port speed regardless of the modem-to-modem or Data Communications Equipment (DCE) speed.

RingsBeforeAnswer
Data type: uint8
Access type: Read-only

Number of rings before the modem answers an incoming call. This property is inherited from CIM_PotsModem.

SpeakerModeDial
Data type: string
Access type: Read-only

Command string used to turn the modem speaker on after dialing a number, and turning the speaker off when a connection has been established.

Example: "M1"

SpeakerModeOff
Data type: string
Access type: Read-only

Command string used to turn the modem speaker off.

Example: "M0"

SpeakerModeOn
Data type: string
Access type: Read-only

Command string used to turn the modem speaker on.

Example: "M2"

SpeakerModeSetup
Data type: string
Access type: Read-only

Command string used to instruct the modem to turn the speaker on (until a connection is established).

Example: "M3"

SpeakerVolumeHigh
Data type: string
Access type: Read-only

Command string used to set the modem speaker to the highest volume.

Example: "L3"

SpeakerVolumeInfo
Data type: uint16
Access type: Read-only

Describes the volume level of the audible tones from the modem. This property is inherited from CIM_PotsModem.

ValueMeaning
0

Unknown

1

Other

2

Not Supported

3

High

4

Medium

5

Low

6

Off

7

Auto

 

SpeakerVolumeLow
Data type: string
Access type: Read-only

Command string used to set the modem speaker to the lowest volume.

Example: "L1"

SpeakerVolumeMed
Data type: string
Access type: Read-only

Command string used to set the modem speaker to a medium volume.

Example: "L2"

Status
Data type: string
Access type: Read-only
Qualifiers: MaxLen (10)

Current status of the object. Various operational and nonoperational statuses can be defined. Operational statuses include: "OK", "Degraded", and "Pred Fail" (an element, such as a SMART-enabled hard disk drive, may be functioning properly but predicting a failure in the near future). Nonoperational statuses include: "Error", "Starting", "Stopping", and "Service". The latter, "Service", could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is online, yet the managed element is neither "OK" nor in one of the other states. This property is inherited from CIM_ManagedSystemElement.

The values are:

"OK"
"Error"
"Degraded"
"Unknown"
"Pred Fail"
"Starting"
"Stopping"
"Service"
"Stressed"
"NonRecover"
"No Contact"
"Lost Comm"
StatusInfo
Data type: uint16
Access type: Read-only

State of the logical device. If this property does not apply to the logical device, the value 5 (Not Applicable) should be used. This property is inherited from CIM_LogicalDevice.

ValueMeaning
1

Other

2

Unknown

3

Enabled

4

Disabled

5

Not Applicable

 

StringFormat
Data type: string
Access type: Read-only

Type of characters used for text passed through the modem.

The values are:

"ASCII string format"
"DBCS string format"
"UNICODE string format"
SupportsCallback
Data type: boolean
Access type: Read-only

If TRUE, the modem supports callback. This property is inherited from CIM_PotsModem.

SupportsSynchronousConnect
Data type: boolean
Access type: Read-only

If TRUE, synchronous, as well as asynchronous, communication is supported. This property is inherited from CIM_PotsModem.

SystemCreationClassName
Data type: string
Access type: Read-only

Value of the scoping computer's CreationClassName property. This property is inherited from CIM_LogicalDevice.

SystemName
Data type: string
Access type: Read-only

Name of the scoping system. This property is inherited from CIM_LogicalDevice.

Terminator
Data type: string
Access type: Read-only

String that marks the end of a command string.

Example: "<cr"

TimeOfLastReset
Data type: datetime
Access type: Read-only

Date and time the modem was last reset. This property is inherited from CIM_PotsModem.

Tone
Data type: string
Access type: Read-only

Command string that instructs the modem to use tone mode for dialing. The phone line must support tone dialing.

Example: "T"

VoiceSwitchFeature
Data type: string
Access type: Read-only

Command strings used to activate the voice capabilities of a voice modem.

Example: "AT+V"

Remarks

The Win32_POTSModem class is derived from CIM_PotsModem.

Examples

For script code examples, see WMI Tasks for Scripts and Applications and the TechNet ScriptCenter Script Repository.

For C++ code examples, see WMI C++ Application Examples.

Requirements

Minimum supported client

Windows XP

Minimum supported server

Windows Server 2003

Namespace

\root\CIMV2

MOF

CIMWin32.mof

DLL

CIMWin32.dll

See also

Computer System Hardware Classes

 

 

Show:
© 2014 Microsoft