The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties. Properties and methods are in alphabetic order, not MOF order.
- Access
-
- Data type: uint16
- Access type: Read-only
Device access state. This property is inherited from CIM_StorageExtent.
| Value | Meaning |
- 0
| Unknown
|
- 1
| Readable
|
- 2
| Writeable
|
- 3
| Read/Write Supported
|
- 4
| Write Once
|
- Availability
-
- Data type: uint16
- Access type: Read-only
Availability and status of the device. Inherited from CIM_LogicalDevice.
| Value | Meaning |
- 1 (0x1)
| Other
|
- 2 (0x2)
| Unknown
|
- 3 (0x3)
| Running or Full Power
|
- 4 (0x4)
| Warning
|
- 5 (0x5)
| In Test
|
- 6 (0x6)
| Not Applicable
|
- 7 (0x7)
| Power Off
|
- 8 (0x8)
| Offline
|
- 9 (0x9)
| Off Duty
|
- 10 (0xA)
| Degraded
|
- 11 (0xB)
| Not Installed
|
- 12 (0xC)
| Install Error
|
- 13 (0xD)
| Power Save - Unknown
The device is known to be in a power save mode, but its exact status is unknown.
|
- 14 (0xE)
| Power Save - Low Power Mode
The device is in a power save state but still functioning and can exhibit degraded performance.
|
- 15 (0xF)
| Power Save - Standby
The device is not functioning, but can be brought to full power quickly.
|
- 16 (0x10)
| Power Cycle
|
- 17 (0x11)
| Power Save - Warning
The device is in a warning state, though also in a power save mode.
|
- BlockSize
-
- Data type: uint64
- Access type: Read-only
- Qualifiers: Units(Bytes)
Size, in bytes, of the blocks that form this storage extent. If this concept is not valid for the device type, the value is 1. This property is inherited from CIM_StorageExtent.
For more information about using uint64 values in scripts, see Scripting in WMI.
- Caption
-
- Data type: string
- Access type: Read-only
Short description (one-line string) of the object. This property is inherited from CIM_ManagedSystemElement.
- Compressed
-
- Data type: boolean
- Access type: Read-only
If True, the file is compressed. This property is inherited from CIM_ManagedSystemElement.
- ConfigManagerErrorCode
-
- Data type: uint32
- Access type: Read-only
Windows Configuration Manager error code.
| Value | Meaning |
- 0 (0x0)
| Device is working properly.
|
- 1 (0x1)
| Device is not configured correctly.
|
- 2 (0x2)
| Windows cannot load the driver for this device.
|
- 3 (0x3)
| Driver for this device might be corrupted, or the system may be low on memory or other resources.
|
- 4 (0x4)
| Device is not working properly. One of its drivers or the registry might be corrupted.
|
- 5 (0x5)
| Driver for the device requires a resource that Windows cannot manage.
|
- 6 (0x6)
| Boot configuration for the device conflicts with other devices.
|
- 7 (0x7)
| Cannot filter.
|
- 8 (0x8)
| Driver loader for the device is missing.
|
- 9 (0x9)
| Device is not working properly. The controlling firmware is incorrectly reporting the resources for the device.
|
- 10 (0xA)
| Device cannot start.
|
- 11 (0xB)
| Device failed.
|
- 12 (0xC)
| Device cannot find enough free resources to use.
|
- 13 (0xD)
| Windows cannot verify the device's resources.
|
- 14 (0xE)
| Device cannot work properly until the computer is restarted.
|
- 15 (0xF)
| Device is not working properly due to a possible re-enumeration problem.
|
- 16 (0x10)
| Windows cannot identify all of the resources that the device uses.
|
- 17 (0x11)
| Device is requesting an unknown resource type.
|
- 18 (0x12)
| Device drivers must be reinstalled.
|
- 19 (0x13)
| Failure using the VxD loader.
|
- 20 (0x14)
| Registry might be corrupted.
|
- 21 (0x15)
| System failure. If changing the device driver is ineffective, see the hardware documentation. Windows is removing the device.
|
- 22 (0x16)
| Device is disabled.
|
- 23 (0x17)
| System failure. If changing the device driver is ineffective, see the hardware documentation.
|
- 24 (0x18)
| Device is not present, not working properly, or does not have all of its drivers installed.
|
- 25 (0x19)
| Windows is still setting up the device.
|
- 26 (0x1A)
| Windows is still setting up the device.
|
- 27 (0x1B)
| Device does not have a valid log configuration.
|
- 28 (0x1C)
| Device drivers are not installed.
|
- 29 (0x1D)
| Device is disabled. The device firmware did not provide the required resources.
|
- 30 (0x1E)
| Device is using an IRQ resource that another device is using.
|
- 31 (0x1F)
| Device is not working properly. Windows cannot load the required device drivers.
|
- ConfigManagerUserConfig
-
- Data type: boolean
- Access type: Read-only
If True, the device is using a user-defined configuration. This property is inherited from CIM_LogicalDevice.
- CreationClassName
-
- Data type: string
- Access type: Read-only
- Qualifiers: Key, MaxLen(256)
Name of the first concrete class to appear in the inheritance chain used in the creation of an instance. When used with the other key properties of the class, this property allows all instances of this class and its subclasses to be uniquely identified. This property is inherited from CIM_LogicalDevice.
- Description
-
- Data type: string
- Access type: Read-only
Description of the object. This property is inherited from CIM_ManagedSystemElement.
- DeviceID
-
- Data type: string
- Access type: Read-only
- Qualifiers: Key
Unique identifier of the memory array. This property is inherited from CIM_LogicalDevice.
Example: "Memory Array 1"
- ErrorCleared
-
- Data type: boolean
- Access type: Read-only
If True, the error reported in LastErrorCode is now cleared. This property is inherited from CIM_LogicalDevice.
- ErrorDescription
-
- Data type: string
- Access type: Read-only
More information about the error recorded in LastErrorCode, and information on any corrective actions that can be taken. This property is inherited from CIM_LogicalDevice.
- ErrorMethodology
-
- Data type: string
- Access type: Read-only
Types of error checking used by the hardware. This property is inherited from CIM_StorageExtent.
- FileSystem
-
- Data type: string
- Access type: Read-only
Access type: Read-only
File system on the logical disk.
Example: "NTFS"
- FreeSpace
-
- Data type: uint64
- Access type: Read-only
- Qualifiers: Units(Bytes)
Space available on the logical disk. This property is inherited from CIM_LogicalDisk.
For more information about using uint64 values in scripts, see Scripting in WMI.
- InstallDate
-
- Data type: datetime
- Access type: Read-only
Access type: Read-only
Date and time the object was installed. This property does not require a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.
- LastErrorCode
-
- Data type: uint32
- Access type: Read-only
Last error code reported by the logical device. This property is inherited from CIM_LogicalDevice.
- MaximumComponentLength
-
- Data type: uint32
- Access type: Read-only
Contains the maximum length of a file-name component supported by the Windows drive.
Example: 255
- Name
-
- Data type: string
- Access type: Read-only
Object label. This property is inherited from CIM_ManagedSystemElement.
- NumberOfBlocks
-
- Data type: uint64
- Access type: Read-only
Total number of consecutive blocks, each block the size of the value contained in the BlockSize property, which form this storage extent. Total size of the storage extent can be calculated by multiplying the value of the BlockSize property by the value of this property. If the value of BlockSize is 1, this property is the total size of the storage extent. This property is inherited from CIM_StorageExtent.
For more information about using uint64 values in scripts, see Scripting in WMI.
- PNPDeviceID
-
- Data type: string
- Access type: Read-only
Windows Plug and Play device identifier of the logical device. This property is inherited from CIM_LogicalDevice.
Example: "*PNP030b"
- PowerManagementCapabilities
-
- Data type: uint16 array
- Access type: Read-only
Array of the specific power-related capabilities of a logical device. This property is inherited from CIM_LogicalDevice.
| Value | Meaning |
- 0 (0x0)
| Unknown
|
- 1 (0x1)
| Not Supported
|
- 2 (0x2)
| Disabled
|
- 3 (0x3)
| Enabled
The power management features are currently enabled but the exact feature set is unknown or the information is unavailable.
|
- 4 (0x4)
| Power Saving Modes Entered Automatically
The device can change its power state based on usage or other criteria.
|
- 5 (0x5)
| Power State Settable
The SetPowerState method is supported. This method is found on the parent CIM_LogicalDevice class and can be implemented. For more information, see Designing Managed Object Format (MOF) Classes.
|
- 6 (0x6)
| Power Cycling Supported
The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle).
|
- 7 (0x7)
| Timed Power-On Supported
The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle) and Time set to a specific date and time, or interval, for power-on.
|
- PowerManagementSupported
-
- Data type: boolean
- Access type: Read-only
If True, the device can be power-managed (can be put into suspend mode, and so on). The property does not indicate that power management features are currently enabled, only that the logical device is capable of power management. This property is inherited from CIM_LogicalDevice.
- ProviderName
-
- Data type: string
- Access type: Read-only
Network path name to the logical device.
- Purpose
-
- Data type: string
- Access type: Read-only
Free-form string that describes the media and its use. This property is inherited from CIM_StorageExtent.
- QuotasDisabled
-
- Data type: boolean
- Access type: Read-only
If True, quota management is not enabled for this volume.
- QuotasIncomplete
-
- Data type: boolean
- Access type: Read-only
If True, quota management was used but has been disabled. Incomplete refers to the information left in the file system after quota management has been disabled.
- QuotasRebuilding
-
- Data type: boolean
- Access type: Read-only
If True, the file system is setting up for quota management.
- SessionID
-
- Data type: string
- Access type: Read-only
ID of the user's session. The user may be connected using a local login or a terminal session.
- Size
-
- Data type: uint64
- Access type: Read-only
- Qualifiers: Units(Bytes)
Size of the logical disk.
For more information about using uint64 values in scripts, see Scripting in WMI.
- Status
-
- Data type: string
- Access type: Read-only
Current status of the object. Various operational and nonoperational statuses can be defined. Operational statuses include: "OK", "Degraded", and "Pred Fail" (an element, such as a SMART-enabled hard disk drive may function properly, but predicts a failure in the near future). Nonoperational statuses include: "Error", "Starting", "Stopping", and "Service". The Service status applies to administrative work, such as mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is online, but the managed element is neither "OK" nor in one of the other states.
The values are:
- "OK"
- "Error"
- "Degraded"
- "Unknown"
- "Pred Fail"
- "Starting"
- "Stopping"
- "Service"
- StatusInfo
-
- Data type: uint16
- Access type: Read-only
State of the logical device. If this property does not apply to the logical device, the value 5 (Not Applicable) should be used. This property is inherited from CIM_LogicalDevice.
| Value | Meaning |
- 1
| Other
|
- 2
| Unknown
|
- 3
| Enabled
|
- 4
| Disabled
|
- 5
| Not Applicable
|
- SupportsDiskQuotas
-
- Data type: boolean
- Access type: Read-only
If True, then the file system on which this network drive is mapped supports disk quotas.
- SupportsFileBasedCompression
-
- Data type: boolean
- Access type: Read-only
If True, the logical disk partition supports file-based compression, such as is the case with NTFS. This property is False, when the Compressed property is True.
- SystemCreationClassName
-
- Data type: string
- Access type: Read-only
Value of the scoping computer's CreationClassName property. This property is inherited from CIM_LogicalDevice.
- SystemName
-
- Data type: string
- Access type: Read-only
- Qualifiers: Key
Name of the scoping system. This property is inherited from CIM_LogicalDevice.
- VolumeName
-
- Data type: string
- Access type: Read-only
- Qualifiers: Key
Volume name of the logical disk. This property value can have a maximum of 32 characters.
- VolumeSerialNumber
-
- Data type: string
- Access type: Read-only
Volume serial number of the logical disk. This property value can have a maximum of 11 characters. This property is inherited from CIM_LogicalDevice.
Example: "A8C3-D032"
The instances returned for this class are as follows, supposing that user A is enumerating the instances: