SetKeepAliveInterval Method of the Win32_NetworkAdapterConfiguration Class

The SetKeepAliveInterval WMI class static method is used to set the interval separating Keep Alive Retransmissions until a response is received. After a response is received, the delay until the next Keep Alive Transmission is again controlled by the value of the KeepAliveTime property. The connection is terminated after the number of retransmissions specified by the TcpMaxDataRetransmissions property have gone unanswered.

This topic uses Managed Object Format (MOF) syntax. For more information about using this method, see Calling a Method.

Syntax

MOF
uint32 SetKeepAliveInterval(
  [in]  uint32 KeepAliveInterval
);

Parameters

KeepAliveInterval [in]

Value, in milliseconds, for the interval separating Keep Alive Retransmissions until a response is received.

Return Value

Returns a value of 0 (zero) for a successful completion when no reboot is required, 1 (one) for a successful completion when a reboot is required, and a different number if there is an error.

Return codeDescription
0

Successful completion, no reboot required.

1

Successful completion, reboot required.

64

Method not supported on this platform.

65

Unknown failure.

66

Invalid subnet mask.

67

An error occurred while processing an instance that was returned.

68

Invalid input parameter.

69

More than five gateways specified.

70

Invalid IP address.

71

Invalid gateway IP address.

72

An error occurred while accessing the registry for the requested information.

73

Invalid domain name.

74

Invalid host name.

75

No primary or secondary WINS server defined.

76

Invalid file.

77

Invalid system path.

78

File copy failed.

79

Invalid security parameter.

80

Unable to configure TCP/IP service.

81

Unable to configure DHCP service.

82

Unable to renew DHCP lease.

83

Unable to release DHCP lease.

84

IP not enabled on adapter.

85

IPX not enabled on adapter.

86

Frame or network number bounds error.

87

Invalid frame type.

88

Invalid network number.

89

Duplicate network number.

90

Parameter out of bounds.

91

Access denied.

92

Out of memory.

93

Already exists.

94

Path, file, or object not found.

95

Unable to notify service.

96

Unable to notify DNS service.

97

Interface not configurable.

98

Not all DHCP leases could be released or renewed.

100

DHCP not enabled on adapter.

 

Examples

For script code examples, see WMI Tasks for Scripts and Applications and the TechNet ScriptCenter Script Repository.

For C++ code examples, see WMI C++ Application Examples.

Requirements

Minimum supported clientWindows 2000 Professional
Minimum supported serverWindows 2000 Server
MOFCimwin32.mof