PowerWriteValueUnitsSpecifier function
Applies to: desktop apps only
Writes the string used to describe the units of a power setting that supports a range of values. For example "minutes" may be used to describe a timeout setting.
Syntax
DWORD WINAPI PowerWriteValueUnitsSpecifier( __in_opt HKEY RootPowerKey, __in_opt const GUID *SubGroupOfPowerSettingsGuid, __in_opt const GUID *PowerSettingGuid, __in UCHAR *Buffer, __in DWORD BufferSize );
Parameters
- RootPowerKey [in, optional]
-
This parameter is reserved for future use and must be set to NULL.
- SubGroupOfPowerSettingsGuid [in, optional]
-
The subgroup of power settings. This parameter can be one of the following values defined in WinNT.h. Use NO_SUBGROUP_GUID to refer to the default power scheme.
- PowerSettingGuid [in, optional]
-
The identifier of the power setting.
- Buffer [in]
-
The units specifier, in wide (Unicode) characters.
- BufferSize [in]
-
The size of the buffer pointed to by the Buffer parameter.
Return value
Returns ERROR_SUCCESS (zero) if the call was successful, and a nonzero value if the call failed.
Remarks
Changes to the settings for the active power scheme do not take effect until you call the PowerSetActiveScheme function.
Requirements
|
Minimum supported client | Windows Vista |
|---|---|
|
Minimum supported server | Windows Server 2008 |
|
Header |
|
|
Library |
|
|
DLL |
|
See also