Export (0) Print
Expand All

ICE77

ICE77 verifies that custom actions with the msidbCustomActionTypeInScript bit set are sequenced after the InstallInitialize action and before the InstallFinalize action. ICE77 checks the sequence in the InstallExecuteSequence table and AdminExecuteSequence table.

Result

ICE77 posts an error if an in-script custom action is sequenced before the InstallInitialize action or after the InstallFinalize action.

ICE77 posts an error if the InstallInitialize action or the InstallFinalize action is missing.

Example

ICE77 reports the following errors for the example:

InstallFinalize is missing from 'InstallExecuteSequence'. 
CA_InScriptInstall is a in-script custom action. It must be sequenced 
before the InstallFinalize action.
 
CA_InScriptAdmin is a in-script custom action.  It must be sequenced 
in between the InstallInitialize action and the InstallFinalize action 
in the AdminExecuteSequence Sequence table.

CustomAction Table (partial)

ActionType
CA_InScriptInstall1025
CA_InScriptAdmin1026

 

InstallExecuteSequence Table (partial)

ActionSequence
CA_InScriptInstall2000
InstallInitialize1500

 

AdminExecuteSequence Table (partial)

ActionSequence
CA_InScriptAdmin1400
InstallInitialize1500
InstallFinalize6600

 

To fix the errors, sequence the in-script custom actions after the InstallInitialize action and before the InstallFinalize action. The InstallInitialize and InstallFinalize actions must be present in the InstallExecuteSequence table and the AdminExecuteSequence table.