profiler90 Utility
The profiler90 utility launches the SQL Server Profiler tool. The optional arguments listed later in this topic allow you to control how the application starts.
Note: |
|---|
| The profiler90 utility is not intended for scripting traces. For more information, see Introducing SQL Server Profiler. |
profiler90
[ /? ] |
[
{
{ /U login_id [ /P password ] }
| /E
}
{[ /S sql_server_name ] | [ /A analysis_services_server_name ] }
[ /D database ]
[ /T "template_name" ]
[ /B { "trace_table_name" } ]
{ [/F "filename" ] | [ /O "filename" ] }
[ /L locale_ID ]
[ /M "MM-DD-YY hh:mm:ss" ]
[ /R ]
[ /Z file_size ]
]
- /?
-
Displays the syntax summary of profiler90 arguments.
- /U login_id
-
Is the user login ID for SQL Server Authentication. Login IDs are case sensitive.
Note: When possible, use Windows Authentication..
- /P password
-
Specifies a user-specified password for SQL Server Authentication.
- /E
-
Specifies connecting with Windows Authentication with the current user's credentials.
- /S sql_server_name
-
Specifies an instance of SQL Server. Profiler will automatically connect to the specified server using the authentication information specified in the /U and /P switches or the /E switch. To connect to a named instance of SQL Server, use /S sql_server_name\instance_name.
- /A analysis_services_server_name
-
Specifies an instance of Analysis Services. Profiler will automatically connect to the specified server using the authentication information specified in the /U and /P switches or the /E switch. To connect to a named instance of SQL Server use /A analysis_services_server_name\instance_name.
- /D database
-
Specifies the name of the database to be used with the connection. This option will select the default database for the specified user if no database is specified.
- /B " trace_table_name "
-
Specifies a trace table to load when the profiler is launched. You must specify the database, the user or schema, and the table.
- /T "template_name"
-
Specifies the template that will be loaded to configure the trace. The template name must be in quotes. The template name must be in either the system template directory or the user template directory. If two templates with the same name exist in both directories, the template from the system directory will be loaded. If no template with the specified name exists, the standard template will be loaded. Note that the file extension for the template (.tdf) should not be specified as part of the template_name. For example:
/T "standard"
- /F "filename"
-
Specifies the path and filename of a trace file to load when profiler is launched. The entire path and filename must be in quotes. This option cannot be used with /O.
- /O " filename "
-
Specifies the path and filename of a file to which trace results should be written. The entire path and filename must be in quotes. This option cannot be used with /F.
- /L locale_ID
-
Not available.
- /M " MM-DD-YY hh:mm:ss "
-
Specifies the date and time for the trace to stop. The stop time must be in quotes. Specify the stop time according to the parameters in the table below:
Parameter Definition MM
Two-digit month
DD
Two-digit day
YY
Two-digit year
hh
Two-digit hour on a 24-hour clock
mm
Two-digit minute
ss
Two-digit second
- /R
-
Enables trace file rollover.
- /Z file_size
-